Warnings, Cautions, Conformance to standards – ElmoMC SimplIQ Analog Servo Amplifiers-Violin Installation User Manual
Page 5: 1 warnings, 2 cautions, 3 conformance to standards

1.1 Warnings
Cleaning after soldering
To avoid the damage of the product's acrylic coating the Violin must not
be cleaned after soldering by dissolving solvents and /or "water"
cleaning process. For more details:
To avoid electric arcing and hazards to personnel and electrical contacts,
never connect/disconnect the servo amplifier while the power source is
on.
Power cables can carry a high voltage, even when the motor is not in
motion. Disconnect the Violin from all voltage sources before it is opened
for servicing.
After shutting off the power and removing the power source from your
equipment, wait at least 5 minutes before touching or disconnecting parts
of the equipment that are normally loaded with electrical charges (such as
capacitors or contacts). Measuring the electrical contact points with a
meter before touching the equipment is recommended.
1.2 Cautions
The Violin servo amplifier contains hot surfaces and electrically-charged
components during operation.
The maximum DC power supply connected to the instrument must comply
with the parameters outlined in this guide.
1.3
Conformance to Standards
The Violin servo amplifier has been developed, produced, tested and documented in
accordance with the relevant standards. Elmo Motion Control is not responsible for any
deviation from the configuration and installation described in this documentation.
Furthermore, Elmo is not responsible for the performance of new measurements or
ensuring that regulatory requirements are met.
The Violin servo amplifier is intended for incorporation in a machine or end product. The
actual end product must comply with all safety aspects of the relevant requirements of
the European Safety of Machinery Directive 89/392/EEC as amended, and with those of
the most recent versions of standards EN60204-1 and EN292-2 at the least.
Violin Installation Guide Safety
Information
MAN-VIOIG (Ver. 2.3)
1-2