Violin Installation Guide
Servo Control Operation
MAN-VIOIG (Ver. 2.3)
4-5
4.8 Status
Indications
The following table lists the Violin amplifier status indications.
Function
Latch
Option
AOK
SO1
SO2
SO3
1 Amplifier
OK
(AOK)
N/A
Low
Open collector Open collector Open collector
2
External disable No
Low
Low
Open collector Low
3
Current limit
No
Low
Open collector Open collector Low
4
Short
Yes
Open collector Low
Open collector Low
5 Over
temperature
Yes
Open collector Open collector Low
Low
6 Internal
supplies
protection
No
Open
collector
Low Low Open
collector
7
Under voltage
No
Open collector Low
Open collector Open collector
8
Over voltage
No
Open collector Open collector Low
Open collector
9
Shunt*
No
Low
Open collector Low
Open collector
10 Power Up Reset No
Open collector Open collector Open collector Open collector
* This indication can be used as a digital input for activating an external shunt regulator.
Table 4-3: Violin Status Indications
Notes:
Without latch mode:
The status indications are reset when the fault disappears.
With latch mode:
The Short and Over Temperature Failure status indications are reset when the
enable signal is temporarily removed from the enable input.
Multiple faults:
Only the reading of the first fault is reliable. Additional faults add on to the
status outputs and the indication is therefore meaningless.