Caution – Elkhart Brass Sidewinder 7100 EXM Monitor User Manual
Page 5

5
SYSTEM COMPONENTS
MONITOR
Monitor – 7100
The
monitor is specially designed for severe
duty cycles. Unique waterway swivel joints utilize stainless steel thrust
rods and needle roller thrust bearings for unprecedented durability in
mining, construction, and wild land firefighting applications. The
monitor can be controlled by hardwired input devices via CAN bus or
by an optional upgraded Radio Frequency (RF) device. The monitor
may be powered with 12 or 24 Volts.
High power, permanent magnet variable speed DC gear motors that
drive the left-right and up-down monitor motions are NEMA 4 rated for
use in harsh environments. The
monitor has
a flow efficient 2¼” vaned waterway to minimize turbulence and
provide superior nozzle streams. The water supply connection in the
monitor base is a 2½” female national pipe thread, and the discharge
nozzle connection has a 2½” national hose male thread.
An optional 2½” electric valve kit is available to allow the user to
control water flow directly from the EXM input device. This enables
“pump and roll” functionality with complete control by the operator in
the cab.
Caution:
All EXM monitor motors are 12VDC. If using a non-EXM nozzle, another
12VDC nozzle should be used, or nozzle control may not function properly.
NOZZLE
Nozzles –
There are four nozzles available for the
.
6000-200E & 6000-700E
Each nozzle has a range of manually selectable flow rates and a flush
setting. The nozzles provide a constant flow in each of the flow settings.
The stream pattern adjustment is electronically actuated and controlled
using the monitor controller(s). Both of the nozzles are rated at 100 psi.
6000-200E; 15, 30, 45, 60, 95, 125, 150, & 200 GPM.
6000-700E; 250, 350, 500, & 700 GPM.
SM-500E & SM-1000E
Each nozzle automatically adjusts to maintain effective stream
and maximum reach at variable flows. These nozzles have been
calibrated to work at lower pressures, from 75 to 80 PSI, to better
suit real world conditions.
SM-500E; 350 GPM @ 75 PSI - 1000 GPM @ 75 PSI
SM-1000E; 350 GPM @ 65 PSI - 1000 GPM @ 75 PSI
Sidewinder EXM Nozzles
(P/N: 06000201 & 06000701)
SM-500E (P/N: 03780817) &
SM-1000E (P/N: 03781501)
Sidewinder EXM Monitor
(P/N: 00007101)