Iii. c, Ontrol, Ystem – Elkhart Brass Sidewinder 8494 Monitor User Manual
Page 10: Pecifications, A. monitor controller specifications, B. optional valve controller specifications
6
III. C
ONTROL
S
YSTEM
S
PECIFICATIONS
A. Monitor Controller Specifications
• Power requirements
12VDC - 11VDC to 14VDC
24VDC - 22 VDC to 27 VDC
• Maximum Continuous Amps
12VDC - 5 A
24VDC – 2.5 A
• Peak Amps
12VDC - 14 A
24VDC - 7 A
• Operating temperature range
-40
°F to 176°F (-40°C to 80°C)
• Required inline fuse
12VDC - 10 A
24VDC - 5 A
B. Optional Valve Controller Specifications
• Power requirements
12VDC - 11VDC to 14VDC
24VDC - 22 VDC to 27 VDC
• Maximum Continuous Amps
12VDC - 5 A
24VDC – 2.5 A
• Peak Amps
12VDC - 14 A
24VDC - 7 A
• Operating temperature range
-40
°F to 176°F (-40°C to 80°C)
• Required inline fuse
(One fuse can be used to protect both the
monitor and valve controllers.)
12VDC - 10 A
24VDC - 5 A
Shock:
• 30 G's (55 Hz. @ .2 inch double amplitude)
Vibration:
• 15.5 G's (55 Hz. @ .05 inch double amplitude) continuous operation
Environmental:
• NEMA 4 rating (except 81172001 Joystick Assembly and 81122001 Switch Box Assembly) (must withstand a 1
inch stream of water (65 gpm) from a distance of ten feet for five minutes, with no water entering the enclosure).