Mf45, And overtemperature controller when fitted), Fuses & power settings – Carbolite CAF 16/38 User Manual
Page 13: On 8.1
CAF16
MF45 1.05
13
F
USES
&
P
OWER
S
ETTINGS
8.1 Fuses
F1-F3: Refer to the circuit diagrams.
F1
Internal
supply
fuses
Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.
on-board and up to 16 Amps:
32mm x 6mm type F
other: GEC Safeclip
F2
Auxiliary
circuit
fuses
Fitted on board to some types of EMC filter.
May be omitted up to 25Amp/phase supply
rating.
2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm
F3
Heat Light
fuses
May be omitted up to 25 Amp/phase supply
rating.
2 Amps glass type F
32mm x 6mm
Customer
fuses
Required if no supply cable fitted.
Recommended if cable fitted.
See rating label for amperage;
see table below for fuse rating.
Model
phases
Volts
Supply Fuse
Rating
Volts
Supply Fuse
Rating (type)
CAF 16/38
1-phase
220-240
25A
110-120
50A
8.2 Power Settings
The power limit parameter OP.Hi is set to 100%.