VCF


14

MF25 – 3.09

8.0 F

USES

&

P

OWER

S

ETTINGS

8.1 Fuses

F1-F3: Refer to the circuit diagrams.

F1

Internal
supply
fuses

Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.

on-board and up to 16 Amps:
32mm x 6mm type F
other: GEC Safeclip

F2

Auxiliary
circuit
fuses

Fitted on board to some types of EMC filter.
May be omitted up to 25Amp/phase supply
rating.

2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm

F3

Heat Light
fuses

May be omitted up to 25 Amp/phase supply
rating.

2 Amps glass type F
32mm x 6mm

Customer
fuses

Required if no supply cable fitted.
Recommended if cable fitted.

See rating label for amperage;
see table below for fuse rating.

Model

phases

Volts

Supply Fuse
Rating

Volts

Supply Fuse
Rating

VCF 12/5

1-phase

200-240

12.5A

100-120

25A

VCF 12/10

1-phase

230-240

12.5A

120

25A

VCF 12/10

1-phase

208-220

16A

110

32A

VCF 12/10

1-phase

200

20A

100

40A

VCF 12/23

1-phase

220-240

25A

VCF 12/23

2-phase

380/220-415/240

12.5A

VCF 12/23

3-phase

380/220-415/240

12.5A

220-240 delta 16A

VCF 12/100 1-phase

220-240

80A

VCF 12/100 3-phase

380/220-415/240

25A

220-240 delta 40A

8.2 Power Settings

The power limit settings (parameter

OP.Hi

) for the VCF models on various supply voltages are as

follows. The figures represent the maximum percentage of time that controlled power is supplied

to the elements. Do not attempt to “improve performance” by setting a value higher than the
correct one from the table.

Model

Volts: 100V 110V 120V 200V 208V 220V 230V 240V 254V

VCF 12/5

100

100

84

100

93

100

91

84

75

VCF 12/10

100

100

100

100

93

100

100

100

89

VCF 12/23

100

100

100

100

89

VCF 12/100

100

100

91

84

75

Model

Volts: 380V 400V 415V 440V 460V 480V

VCF 12/23

100

100

100

89

81

75

VCF 12/100

100

91

84

75

68

63