beautypg.com

Repairs & replacements – Carbolite HTMA Series User Manual

Page 9

background image

High Temperature Ovens


MF16 3.09

9

5.0 R

EPAIRS

&

R

EPLACEMENTS

5.1 Safety Warning – Disconnection from Supply

Always ensure that the oven is disconnected from the supply before repair work is
carried out.

5.2 Safety Warning - Refractory Fibrous Insulation

Insulation made from High Temperature Insulation Wool

Refractory Ceramic Fibre, (better described as Alumino Silicate Wool) (ASW)

This product contains alumino silicate wool products in its thermal insulation. These materials
may be in the form of blanket or felt, formed board or shapes, mineral wool slab or loose fill wool.

Whilst there is no evidence of any long term health hazards, we strongly recommend that safety
precautions are taken whenever the materials are handled.

Exposure to fibrous dust may cause respiratory disease.

When handling the material always use an approved respiratory protection equipment
(RPE-i.e. FFP3), eye protection, gloves and long sleeved clothing.

Avoid breaking up waste material. Dispose of waste in sealed containers.

After handling rinse exposed skin with water before washing gently with soap (not
detergent). Wash work clothing separately.

Before commencing any major repairs we recommend reference to the European Association
representing the High Temperature Insulation Wool industry (www.ecfia.eu)

We can provide further information on request. Alternatively our service division can quote for
any repairs to be carried out at your premises or ours.

5.3 Panel Removal

Disconnect the oven from the electrical supply.

Control panel - LHT Models. Open the door and remove two screws located in recesses on the left
side of the control panel (these screws are covered with plastic caps). Lift the panel, pull forward
the bottom of the panel, and lower the panel to disengage it from the top of the body. Note that the
panel remains connected by wiring. Do not disconnect any wiring without first making a careful
note of all the connections.

Control panel - HT models. Remove the screws holding the panel. Note that the panel remains
connected by wiring. Do not disconnect any wiring without first making a careful note of all the
connections.

Internal Element Cover. Open the door. Remove any screws holding the panel and any clips
holding thermocouples in position. Remove the cover.

5.4 Temperature Controller Replacement

200 & 201. These controllers are fitted to the back of the control panel, which can be removed as
given above.

Before handling the controller: wear an anti-static wrist strap or otherwise avoid any possibility
of damage to the unit by static electricity.

Refer to the instructions supplied with the replacement controller.

2132, 2416, 2408 etc. Ease apart the two lugs at the side; grip the instrument and withdraw it from
its sleeve; push in the replacement.

This manual is related to the following products: