Instructions
PN 7635 / 7635B
Blue Sea Systems Inc.
p 360.738.8230
425 Sequoia Drive
f 360.734.4195
Bellingham, WA 98226 USA
www.bluesea.com
980016770 Rev.002
WARNING
CAUTION
Installation
GUARANTEE: Blue Sea Systems stands behind its products for as long
as you own them. Find detailed information at www.bluesea.com/about.
For customer service, call 800-222-7617.
Senses low battery voltage and automatically disconnects
devices to save power for starting or to preserve battery life
• Status light in both
m
-LVD and Remote Control Switch provides visual warning of low
voltage state prior to disconnect
• Alarm output available for audible warning of low voltage state
prior to disconnect (optional alarm required)
• Remote Control Switch Functions:
Disconnect Voltage Adjustment - Sets desired disconnect voltage
Override - Temporarily delays circuit disconnect for 10 minutes
OFF
- Temporarily disconnects circuits until voltage rises
Override or OFF - Silences alarm (optional alarm required)
• Includes Remote Control Switch PN 7928
DC
AC
Before beginning electrical installation, disconnect all AC and DC power sources.
Do not service equipment that has been automatically disconnected by the
m
-LVD
without first permanently removing power from the equipment by a means other
than the
m
-LVD.
WARNING
CAUTION
If you are not knowledgeable about electrical systems, consult an electrical professional.
Mount the
m
-LVD. Three mounting options are illustrated below:
1.00" (25.4mm)
SUGGESTED
MINIMUM SCREW
LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
2-5/8" (66.7mm)
MOUNTING HOLE
DIAMETER
5/16" (7.9mm)
MAXIMUM PANEL
THICKNESS
2-5/16" (58.7mm)
MOUNTING HOLE
DIAMETER
1.00
" (25.4mm)
SUGGESTED SCREW
LENGTH FOR 1/8"
PANEL THICKNESS
#10 HEX NUTS
3/8" WIDTH
#10 MACHINE
SCREWS
2.25 (57.2mm)
SUGGESTED MINIMUM
SCREW LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
Rear Panel Mount
Front Panel Mount
Surface Mount
Front Panel Mount (Rear View)
m
-LVD
LOW VOLTAGE DISCONNECT
Scan for
additional
product
information
1.45"
(36.83mm)
0.83"
(21.08mm)
Remote Control Switch
Mounting Hole Dimensions
Intermittent Rating: 5 min.
115A
Continuous Rating
65A
Nominal Voltage
12V DC
Cable Size
(to meet current ratings)
6 AWG (16mm²)
Terminal Stud Size
1/4"-20 (M6)
Disconnect Voltage
11.3V–12.1V Adjustable
Factory Default Disconnect Voltage
12.1V
Alarm Time Before Disconnect
5 minutes
Reconnect Voltage
13V DC
Remote Control Switch
Type: SPDT, Action: (ON)-OFF-(ON)
( ) = momentary
Maximum Alarm Current
250mA
Maximum External LED Current
14mA
Regulatory
ISO 8846, Meets SAE J1171 external ignition protection requirements
Specifications
Installation
(continued)
Remove rear insulating cover as illustrated.