1. Disconnect all AC and DC power

Disconnect all AC power originating on or off the vessel. This includes
inverters, generators, shore power attachments and any other device
capable of supplying AC power to the ship’s circuits.

Disconnect the main positive DC cable from all batteries to eliminate the
possibility of a short circuit and to disable the inverter while installing the
distribution panel.

2. Select mounting location and cut opening

If this panel is to serve as your main shore power disconnect circuit
breaker, select a location which is not more than 10 feet from the shore
power inlet or the electrical attachment point of a permanently installed
shore power cord as measured along the conductors of the feed wires. If
it is more than 10 feet, additional fuses or circuit breakers must be
installed within 10 feet of the shore power inlet.

Select a mounting location which is protected from water on the panel
front and back and is not in an area where flammable vapors from
propane, gasoline or lead acid batteries accumulate. The circuit breakers
used in marine electrical panels are not ignition protected and may ignite
such vapors.

Using the panel template provided, make a cutout in the mounting
surface where the distribution panel is to be mounted. Do not yet fasten
the panel to the mounting surface.

Page 1 of 4

WARNING

Blue Sea Systems Inc.

Phone (360) 738-8230

425 Sequoia Drive

Fax (360) 734-4195

Bellingham, WA 98226 USA

www.bluesea.com

Installation Set Up

1. Select positive feed wire and negative return

Determine the positive feed (red) and negative return (black or yellow)
wire size by calculating the total amperage of the circuits that will be
routed through the panel. Blue Sea Systems electrical panels are rated
at 100 amp total capacity. The positive feed wire must be sized for 3%
voltage drop at the 100 amp panel rating or the maximum amperage
that will be routed through the panel in any particular installation,
whichever is less. It is recommended that the positive feed wire be sized
for the full panel capacity, which, in most cases, will require at least 2
AWG wire, assuming a 10 foot wire run between the panel and the
batteries in 12 volt systems. Refer to the Wire Sizing Chart for other
situations. In the case of panels with two or more columns of breakers,
jumpers from positive bus to positive bus and from negative bus to
negative bus should be the same size as the positive feed and the
negative return wires.

Remember that the length of the circuit is the total of the positive wire
from the power source and the negative wire back to the DC Negative
Bus. Be certain that there is a fuse or circuit breaker of the correct size
protecting the positive feed wire.

2. Install battery bank voltage monitor wires

The panel is supplied with a voltmeter and switch to monitor the

voltage of three separate sources, usually the batteries. Connect a
minimum 16 AWG red wire from each source to be monitored to each of
the corresponding input wires of the switch. There should be a 1 ampere
fuse in each positive wire near each source.

DC Installation

]

These instructions are intended to provide assistance with the

installation of this product, and are not a substitute for a more
comprehensive understanding of electrical systems. We strongly
recommend that a competent electrical professional perform the
installation of this product.

]

If either the panel front or back is to be exposed to water it must be

protected with a waterproof shield.

]

The panels must not be installed in explosive environments such as

gasoline engine rooms or battery compartments as the circuit breakers

are not ignition protected.

]

The vessel’s shore power cord must be disconnected form shoreside

power before installing this electrical panel.

]

If an inverter is installed on the vessel its power leads must be

disconnected at the battery before the panel installation. Be aware that

many inverters have a “sleep mode” in which their voltage potential

may not be detectable with measuring equipment.

]

If an AC Generator is installed aboard it must be stopped and rendered

inoperable before the panel is installed.

]

Verify that no other AC source is connected to the vessel’s wiring

before the panel is installed.

]

Do not connect AC Source to transfer position as a potential AC conflict

could occur. See wiring diagram.

Questions and Comments

We invite your questions and comments. You may contact us at the address

below. To find out more about our full line of marine electrical products visit

our web site at www.bluesea.com.

Guarantee

Any Blue Sea Systems product with which a customer is not satisfied may

be returned for a refund or replacement at any time.

AC & DC Power Distribution Panel

PN 8086 / PN 3086 / PN 8186 / PN 3186

20 Position AC / 20 Position DC

Specifications

Material:

0.125" 5052-H32 aluminum alloy

Primary Finish:

Chemical treatment per MIL SPEC C-5541C

Final Panel Finish:

Graphite color 2 part textured polyurethane

Maximum Amperage:

Varies by components: busbar maximum 100A

Voltage Rating:

8086 / 3086 12 Volts DC* / 120 Volts AC

8186 / 3186 12 Volts DC* / 230 Volts AC

Inches

Millimeters

Overall Dimensions:

19-1/2 Ч 11-1/2 495.30 Ч 292.20

* Panels can be upgraded to 24 volts with PN 8240, 18-32V DC voltmeter.

Features

AC 8086 / 3086 / 8186 / 3186
• 2 separate AC groups with transfer switch to combine into one load group
• 20 AC circuit breaker positions
• 0-50 Ampere AC ammeter with remote sensing coil
AC 8086 / 3086
• Six 15 Ampere branch circuit breakers installed
• Three double pole 30 Ampere AC main circuit breakers and one double
pole 50 Ampere circuit breaker with lockout slides
• 0-150 Volt AC voltmeter
AC 8186 / 3186
• Six 8 Ampere branch circuit breakers installed
• Three double pole 16 Ampere AC main circuit breakers and one double
pole 32 Ampere circuit breaker with lockout slides
• 0-250 Volt AC voltmeter
DC 8086 / 3086 / 8186 / 3186
• One 100A C-Series DC main circuit breaker
• 19 DC circuit breaker positions, thirteen 15A circuit breakers installed
• 8-16 Volt voltmeter with 3 position switch for multiple battery banks
• 0-100A DC ammeter with remote shunt

9866 Rev. 009