Blue Sea Systems 8015 DC analog Voltmeter Panel - 8 to 16V DC User Manual
Installation, Analog dc voltmeter, Continued)
8-16 Volts PN 8003 / PN 8028
Meter Specifications
Input Voltage:
8 Volts DC to 16 Volts DC
Amperage Draw: 1 Milliampere
Display:
Analog scale 8-16 Volts
Accuracy:
3% of scale range (.24 Volt)
PN
Inches
Millimeters
Face Width:
8003 2-1/2
63.50
8028 2
50.80
Mounting Hole: 8003 1-7/8
47.60
8028 1-1/2
38.10
Guarantee
Any Blue Sea Systems product with which
a customer is not satisfied may be returned
for a refund or replacement at any time.
Marine Electrical Products
Warning
It is not possible within the scope of these
instructions to fully acquaint the installer
with all the knowledge of electrical systems
that may be necessary to correctly install
this product. If the installer is not
knowledgeable in electrical systems we
recommend that an electrical professional
be retained to make the installation.
1. Disconnect all AC and DC power
Before starting, disconnect the main
positive cable from all batteries to eliminate
the possibility of a short circuit while
installing the meter panel. Also disconnect
the AC shore power cord from the boat to
eliminate the possibility of electrocution
from AC wiring near the DC meter.
2. Select mounting location and
cut opening
Select a mounting location which is
protected from water on the meter front and
back and is not in an area where flammable
vapors from propane, gasoline or lead acid
batteries accumulate. The meter is not
ignition protected and may ignite such
vapors. There are two mounting methods
for the 8028 and 8003 meters, surface
mount or panel mount.
Blue Sea Systems Inc.
425 Sequoia Drive Bellingham, WA 98226 USA
Phone (360) 738-8230 Fax (360) 734-4195
E-mail [email protected]
www.bluesea.com
(
Installation
(continued)
Analog DC Voltmeter
Document 9310 Rev.D
PN 8028
PN 8003
Surface Mount
Panel Mount
3.
Surface Mount: Drill five clearance holes as shown below. The part number of the meter will
determine the size and location of the clearance holes. Use the nuts and washers supplied in the
accessory package to secure the four mounting studs to the mounting surface. This method will
work on mounting surfaces up to 5/8” thick.
Installation
PN 8028
Micro Meter
PN 8003
Standard Meter