beautypg.com

Blue Sea Systems 7509 Deckhand Dimmer - 24V DC 12A User Manual

Deckhand dimmer 12a, Pn 7509

background image

425 Sequoia Drive

Bellingham, WA 98226 USA

p 360.738.8230

p 800.222.7617 USA and Canada

f 360.734.4195

[email protected]

www.bluesea.com

Lamp (blue)

Brightness Control

(ON)-OFF-(ON) Switch

Optional

Light Switch

Down Position

For Dim (ON)

OFF

D

ECK

H

AND

DIMMER

( ) = momentary

24V DC

Fuse

Up Position

For Bright (ON)

Negative Bus Bar

Up Input (white)

+24V DC (red)

Down Input (gray)

Ground (black)
Ground (black)

Ground (black)

DeckHand Dimmer 12A

PN 7509

980010680 Rev. 002

The illuminated exit setting allows boaters to safely disembark before

the lights automatically turn off.

Features

• Digitally controls dimming of non-regulated LEDs, incandescent, and halogen lights

• Illuminated exit with adjustable time delay

• Supports multiple switch locations

• Memory for last dimmer setting

• Bulb saver prevents excessive bulb aging while boat’s batteries are being charged

• Offset mounting tabs allow dimmers to be mounted close together

• Includes momentary (ON)-OFF-(ON) switch

Overcurrent Protection

DeckHand Dimmers have a built in overcurrent protection. If the unit stops working,

correct the over current load, then hold the dimmer switch down until the circuit flashes.

Specifications

Nominal Voltage

24V DC

Operating Range

18V to 32V

Maximum Output Current

12A

Maximum Parasitic Current

<2mA

Temperature Range

−40°C to 85°C

Control Type

Pulse With Modulation (PWM)

Regulatory

E

marked, Meets ISO 8846 and SAE J1171 external ignition protection requirements

Using the illuminated exit mode

1 minute delay: Hold the switch in up position (bright) for 2 seconds, lights will flash.

Release switch after first flash and the lights will remain on for 1 minute.
2-5 minute delay: Hold the switch in up position (bright) for 1-4 seconds after the

first flash. Release the switch after 2 to 5 flashes. The lights will remain on for 1

minute for each flash up to a maximum of 5 minutes.