beautypg.com

Blue Sea Systems 8005 DC Analog Ammeter - 0 to 25A with Shunt User Manual

Analog dc ammeter, Installation, Continued)

background image

0-15

Amperes PN 8038

0-25

Amperes PN 8005

Meter Speci

fi cations

Input V

oltage:

8 V

olts DC to 16 V

olts DC

Amperage Draw:

1 Milliamp at full scale

Display: Analog

scale

Accuracy:

3% of scale range

PN

Inches

Millimeters

Face Width:

8038

2

50.80

8005

2-1/2

63.50

Mounting Hole:

8038

1-1/2

38.10

8005

1-7/8

47.60

Guarantee

Any Blue Sea Systems product with which

a customer is not satis

fi ed may be returned

for a refund or replacement at any time.

W

arning

It is not possible within the scope of these instructions to fully acquaint the installer with all the knowledge of electrical systems that may be necessary to correctly install this product. If the installer is not knowledgeable in electrical systems we recommend that an electrical professional be retained to make the installation.

1.

Disconnect all

AC and DC power

Before starting, disconnect the main positive cable from all batteries to eliminate the possibility of a short circuit while installing the meter

. Also disconnect the

AC

shore power cord from the boat to eliminate the possibility of electrocution from

AC

wiring near the DC ammeter

.

2.

Select mounting location

Select a mounting location which is protected from water on the meter front and back and is not in an area where

fl ammable

vapors from propane, gasoline or lead acid batteries accumulate.

The meter is not

ignition protected and may ignite such vapors.

There are two mounting methods

for the 8038 and 8005 ammeters, surface mount or panel mount.

Analog DC

Ammeter

Surface Mount:

Drill

fi ve clearance holes a shown below

. The part number of the meter will

determine the size and location of the clearance holes. Use the nuts and washers supplied in the

accessory package to secure the four mounting studs to the mounting surface.

This method will

work on mounting surfaces up to 5/8” thick.

PN 8038

PN 8005

Panel Mount:

For thicker mounting surfaces, the meter can be mounted into a 0.125” thick

panel. Blue Sea Systems of

fers meter mounting panels for our standard size meters only

. For

part number 8005 use part number 8013 to mount a single meter or part number 8014 to mount

two meters.

Marine Electrical

Prod

ucts

(

Installation

(continued)

Installation

Blue Sea Systems Inc.

425 Sequoia Drive Bellingham, W

A 98226 USA

Phone (360) 738-8230 Fax (360) 734-4195

E-mail conduct @ bluesea.com

www

.bluesea.com

Document 9289 Rev

.D

0-15

Amperes PN 8038

0-25

Amperes PN 8005

Meter Speci

fi cations

Input V

oltage:

8 V

olts DC to 16 V

olts DC

Amperage Draw:

1 Milliamp at full scale

Display: Analog

scale

Accuracy:

3% of scale range

PN

Inches

Millimeters

Face Width:

8038

2

50.80

8005

2-1/2

63.50

Mounting Hole:

8038

1-1/2

38.10

8005

1-7/8

47.60

Guarantee

Any Blue Sea Systems product with which

a customer is not satis

fi ed may be returned

for a refund or replacement at any time.

W

arning

It is not possible within the scope of these instructions to fully acquaint the installer with all the knowledge of electrical systems that may be necessary to correctly install this product. If the installer is not knowledgeable in electrical systems we recommend that an electrical professional be retained to make the installation.

1.

Disconnect all

AC and DC power

Before starting, disconnect the main positive cable from all batteries to eliminate the possibility of a short circuit while installing the meter

. Also disconnect the

AC

shore power cord from the boat to eliminate the possibility of electrocution from

AC

wiring near the DC ammeter

.

2.

Select mounting location

Select a mounting location which is protected from water on the meter front and back and is not in an area where

fl ammable

vapors from propane, gasoline or lead acid batteries accumulate.

The meter is not

ignition protected and may ignite such vapors.

There are two mounting methods

for the 8038 and 8005 ammeters, surface mount or panel mount.

Analog DC

Ammeter

Surface Mount:

Drill

fi ve clearance holes a shown below

. The part number of the meter will

determine the size and location of the clearance holes. Use the nuts and washers supplied in the

accessory package to secure the four mounting studs to the mounting surface.

This method will

work on mounting surfaces up to 5/8” thick.

PN 8038

PN 8005

Panel Mount:

For thicker mounting surfaces, the meter can be mounted into a 0.125” thick

panel. Blue Sea Systems of

fers meter mounting panels for our standard size meters only

. For

part number 8005 use part number 8013 to mount a single meter or part number 8014 to mount

two meters.

Marine Electrical

Prod

ucts

(

Installation

(continued)

Installation

Blue Sea Systems Inc.

425 Sequoia Drive Bellingham, W

A 98226 USA

Phone (360) 738-8230 Fax (360) 734-4195

E-mail conduct @ bluesea.com

www

.bluesea.com

Document 9289 Rev

.D

This manual is related to the following products: