beautypg.com

BernzOmatic GHA-096 User Manual

8' appliance conversion hose, Danger, Peligro

background image

GHA-096

8' Appliance Conversion Hose

DANGER

Failure to comply with these Warnings and Instructions

may result in an explosion or fire that may cause property

damage, serious personal injury or death.
DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

WARNING

For LP-Gas Only.

For use only with appliances that have a built-in pressure

regulating system.

Read all instructions prior to installation and use.

Disconnection of old hose assembly or installation of new hose

assembly shall take place outdoors in a well-ventilated area.

DO nOt

make modifications to this hose assembly. If the hose

assembly does not fit, return to the original place of purchase

and obtain the correct hose assembly for your gas appliance.

Examine the new hose assembly for damage. Do not use

hose assembly if damaged. If damaged return to the original

place of purchase.

Movement of the gas appliance, removal of old hose assembly

and installation of new hose assembly shall only be done

when appliance is cool.

DO nOt

use appliance until leak testing is complete and any

leaks are corrected.

1"-20 Female

Appliance Connection

1"-20 Male Appliance

Connection

Installation Guidelines for Hose Assembly

turn burner control knob on portable LP-Gas appliance to “off”

1.)

position. turn LP-Gas “off” at cylinder by turning the cylinder

valve handle fully clockwise.

Route the hose to avoid any areas that may cause wear or cut

2.)

the hose. Also avoid contact with any potential hot surfaces on

the appliance. Be sure that the hose does not create a trip hazard.

Position 1-20" female fitting on the hose assembly to the fitting

3.)

on the LP-Gas cylinder valve outlet. Connect by turning hose

assembly fitting clockwise until fully hand tight.

Position 1-20" male swivel fitting on hose assembly to the

4.)

portable LP-Gas appliance female fitting. Connect by turning

knurled section of male swivel fitting clockwise until fully hand

tight.

WARNING

When leak testing the connections:

Conduct leak test outdoors in a well ventilated area.

Do not smoke.

Do not use or permit sources of ignition in the area while

conducting a leak test.

Do not use matches, lighters or flame to check for leaks.

Do not use the appliance until any leaks are corrected.

Leak Testing

Before lighting your appliance, check for leaks by applying a

1.)

mild soapy water solution to all connections. Slowly open the

cylinder valve and check for leaks. the appearance of bubbles

indicates a leak.

Repair any leaks prior to lighting your appliance. If you cannot

2.)

stop a leak by additional tightening of the connection, shut off

the LP-Gas supply at the cylinder valve and have an LP-Gas

service person make the needed repairs.

Disconnection Guidelines for Hose Assembly

turn bur

1.)

ner control knob on portable LP-Gas appliance to “off”

position. turn LP-Gas “off” at cylinder by turning the cylinder

valve handle fully clockwise.

Disconnect hose from portable LP-Gas appliance by turning

2.)

knurled section of male swivel fitting on the hose assembly

counter clockwise.

Disconnect the hose assembly from the LP-Gas cylinder valve

3.)

outlet by turning the 1-20" female fitting on the hose assembly

counter clockwise until it disengages from the LP-Gas cylinder

valve outlet.

When not in use, store the assembly in a clean and dry area.

4.)

WARNING

Materials used in the construction of this device may

contain brass (which may contain lead), a chemical

known to the State of California to cause cancer,

birth defects, or other reproductive harm.

Combustion byproducts produced when using this

device contain chemicals known to the State of

California to cause cancer, birth defects or other

reproductive harm.

• Examine el nuevo conjunto de manguera para verificar que

no esté dañado. No use el conjunto de manguera si este se

encuentra dañado. Si estuviera dañado, devuélvalo al lugar

original de compra.

• Sólo debe moverse el artefacto a gas, quitarse el conjunto de

manguera viejo e instalar un nuevo conjunto de manguera

cuando el artefacto esté frío.

• NO use el artefacto hasta que se finalice la prueba de fugas y

se corrija cualquier fuga presente.

Conexión del artefacto

1 pulg.-20 hembra

Conexión del artefacto

1 pulg.-20 macho

Pautas de instalación para el conjunto de manguera
1.) Gire la perilla del control del quemador del artefacto portátil

de gas LP a la posición “off” (cerrado). Cierre el paso de gas

LP en el cilindro girando la manija de la válvula del cilindro

totalmente hacia la derecha.

2.) Dirija la manguera para evitar cualquier área que pueda causar

desgaste o cortar la manguera. también evite el contacto con

cualquier superficie del artefacto que pueda estar caliente.

Asegúrese de que la manguera no cree un peligro de tropiezo.

Manguera de conversión de 8 pies

(2.4 m) para artefacto

PELIGRO

Si no se cumplen estas advertencias e instrucciones, se

pueden producir una explosión o un incendio que pueden

causar daños materiales, lesiones personales graves o la

muerte.
NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

ADVERTENCIA

• Para gas LP (propano líquido) únicamente.

• Para uso únicamente con artefactos que tengan incorporado

un sistema de regulación de la presión.

• Lea todas las instrucciones antes de instalar y usar.

• La desconexión de un conjunto de manguera viejo o la

instalación de un nuevo conjunto de manguera deben

realizarse al aire libre en un área bien ventilada.

• NO modifique este conjunto de manguera. Si el conjunto de

manguera no calza, devuélvalo al lugar de compra original y

obtenga el conjunto de manguera correcto para su artefacto

a gas.

3.) Coloque el adaptador hembra de 1 pulg.-20 en el conjunto de

manguera en el adaptador de la salida de la válvula del cilindro

de gas LP. Para efectuar la conexión, haga girar el adaptador

del conjunto de manguera hacia la derecha hasta que esté

completamente ajustado a mano.

4.) Coloque el adaptador giratorio macho de 1 pulg.-20 del

conjunto de la manguera en el adaptador hembra del artefacto

portátil de gas LP. Para efectuar la conexión, haga girar la

sección estriada del adaptador giratorio macho hacia la

derecha hasta que esté completamente ajustado a mano.

ADVERTENCIA

Cuando realice la prueba de fugas en las conexiones:

• Realice la prueba de fugas al aire libre en un área bien

ventilada.

• No fume.

• No use ni permita fuentes de ignición en el área mientras

realiza una prueba de fugas.

• No use fósforos, encendedores ni llamas para verificar si hay

fugas.

• No use el artefacto hasta que se corrija cualquier fuga

existente.