4' Appliance Extension Hose

DANGER

Failure to comply with these Warnings and Instructions

may result in an explosion or fire that may cause property

damage, serious personal injury or death.

DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

WARNING

For LP-Gas Only.

For use only with appliances that have a built-in pressure

regulating system.

Read all instructions prior to installation and use.

Disconnection of old hose assembly or installation of new hose

assembly shall take place outdoors in a well-ventilated area.

DO nOt

make modifications to this hose assembly. If the hose

assembly does not fit, return to the original place of purchase

and obtain the correct hose assembly for your gas appliance.

Examine the new hose assembly for damage. Do not use hose

assembly if damaged. If damaged return to the original place

of purchase.

Movement of the gas appliance, removal of old hose assembly

and installation of new hose assembly shall only be done when

appliance is cool.

DO nOt

use appliance until leak testing is complete and any

leaks are corrected.

1"-20 Appliance

Connection

QCC1

Cylinder Connection

Installation Guidelines for Hose Assembly

turn burner control knob on portable LP-Gas appliance to “off”

1.)

position. turn LP-Gas “off” at cylinder by turning the cylinder

valve handle fully clockwise.

Route the hose through any required openings being sure to

2.)

avoid any areas that may cause wear or cut the hose. Also

avoid contact with any potential hot surfaces on the appliance.

Be sure that the hose does not create a trip hazard.

Position male swivel fitting on hose assembly to the portable

3.)

LP-Gas appliance female fitting. Connect by turning knurled

section of male swivel fitting clockwise until fully hand tight.

Connect the plastic coupling nut on the hose assembly to the

4.)

large outside threads on the LP-Gas cylinder valve outlet. Hand

tighten the black plastic coupling nut by turning clockwise

until coming to a full stop. Do not cross thread the connection.

Note: this hose assembly is equipped with a QCC-1 appliance

connection and requires a cylinder equipped with a valve

marked for use with a type 1 connection.

WARNING

When leak testing the connections:

Conduct leak test outdoors in a well ventilated area.

Do not smoke.

Do not use or permit sources of ignition in the area while

conducting a leak test.

Do not use matches, lighters or flame to check for leaks.

Do not use the appliance until any leaks are corrected.

Leak Testing

Before lighting your appliance, check for leaks by applying a

1.)

mild soapy water solution to all connections. Slowly open the

cylinder valve and check for leaks. the appearance of bubbles

indicates a leak.

Repair any leaks prior to lighting your appliance. If you cannot

2.)

stop a leak by additional tightening of the connection, shut off

the LP-Gas supply at the cylinder valve and have an LP-Gas

service person make the needed repairs

Disconnection Guidelines for Hose Assembly

turn burner control knob on portable LP-Gas appliance to “off”

1.)

position. turn LP-Gas “off” at cylinder by turning the cylinder

valve handle fully clockwise.

Disconnect the hose assembly from the LP-Gas cylinder valve

2.)

outlet by turning the plastic coupling nut counter clockwise

until it disengages from the large outside threads on the LP-Gas

cylinder valve outlet.

Disconnect hose from portable LP-Gas appliance assembly by

3.)

turning knurled section of male swivel fitting counter clockwise.

Reinstall the plastic protection cap on the 1"- 20 connection.

4.)

When not in use, store the assembly in a clean and dry area.

5.)

Examine el nuevo conjunto de manguera para verificar que

no esté dañado. no use el conjunto de manguera si este se

encuentra dañado. Si estuviera dañado, devuélvalo al lugar

original de compra.

Sólo debe moverse el artefacto a gas, quitarse el conjunto de

manguera viejo e instalar un nuevo conjunto de manguera

cuando el artefacto esté frío.

nO

use el artefacto hasta que se finalice la prueba de fugas y

se corrija cualquier fuga presente.

Conexión del artefacto

1 pulg.-20

Conexión

del cilindro QCC1

Pautas de instalación para el conjunto de manguera

Gire la perilla del control del quemador del artefacto portátil

1.)

de gas LP a la posición “off” (cerrado). Cierre el pasoe de gas

LP en el cilindro girando la manija de la válvula del cilindro

totalmente hacia la derecha.

Pase la manguera sobre cualquier abertura según sea necesario,

2.)

asegurándose de evitar cualquier área que cause desgaste o

Manguera de extensión de 4 pies

(1.2 m) para artefacto

PELIGRO

Si no se cumplen estas advertencias e instrucciones, se

pueden producir una explosión o un incendio que pueden

causar daños materiales, lesiones personales graves o la

muerte.

NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

ADVERTENCIA

Para gas LP (propano líquido) únicamente.

Para uso únicamente con artefactos que tengan incorporado

un sistema de regulación de la presión.

Lea todas las instrucciones antes de instalar y usar.

La desconexión de un conjunto de manguera viejo o la

instalación de un nuevo conjunto de manguera deben

realizarse al aire libre en un área bien ventilada.

nO

modifique este conjunto de manguera. Si el conjunto de

manguera no calza, devuélvalo al lugar de compra original y

obtenga el conjunto de manguera correcto para su artefacto

a gas.

cortes en la manguera. también evite el contacto con cualquier

superficie del artefacto que pueda estar caliente. Asegúrese de

que la manguera no cree un peligro de tropiezo.

Coloque el adaptador giratorio macho del conjunto de la

3.)

manguera en el adaptador hembra del artefacto portátil de gas

LP. Para efectuar la conexión, haga girar la sección estriada

del adaptador giratorio macho hacia la derecha hasta que esté

completamente ajustado a mano.

Conecte la tuerca de acoplamiento de plástico del conjunto

4.)

de la manguera a las roscas externas grandes de la salida de

la válvula del cilindro de gas LP. Ajuste a mano la tuerca de

acoplamiento negro de plástico girándola hacia la derecha hasta

que se detenga. no fuerce la rosca de la conexión. Nota: Este

conjunto de manguera está equipado con una conexión QCC-1

para artefactos y requiere un cilindro equipado con una válvula

marcada para el uso con una conexión tipo 1.

WARNING

Materials used in the construction of this device may

contain brass (which may contain lead), a chemical

known to the State of California to cause cancer, birth

defects, or other reproductive harm.

Combustion byproducts produced when using this

device contain chemicals known to the State of

California to cause cancer, birth defects or other

reproductive harm.