BernzOmatic GHA-048 User Manual
4' appliance extension hose, Danger, Peligro
GHA-048
4' Appliance Extension Hose
DANGER
Failure to comply with these Warnings and Instructions
may result in an explosion or fire that may cause property
damage, serious personal injury or death.
DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS
WARNING
For LP-Gas Only.
•
For use only with appliances that have a built-in pressure
•
regulating system.
Read all instructions prior to installation and use.
•
Disconnection of old hose assembly or installation of new hose
•
assembly shall take place outdoors in a well-ventilated area.
DO nOt
•
make modifications to this hose assembly. If the hose
assembly does not fit, return to the original place of purchase
and obtain the correct hose assembly for your gas appliance.
Examine the new hose assembly for damage. Do not use hose
•
assembly if damaged. If damaged return to the original place
of purchase.
Movement of the gas appliance, removal of old hose assembly
•
and installation of new hose assembly shall only be done when
appliance is cool.
DO nOt
•
use appliance until leak testing is complete and any
leaks are corrected.
1"-20 Appliance
Connection
QCC1
Cylinder Connection
Installation Guidelines for Hose Assembly
turn burner control knob on portable LP-Gas appliance to “off”
1.)
position. turn LP-Gas “off” at cylinder by turning the cylinder
valve handle fully clockwise.
Route the hose through any required openings being sure to
2.)
avoid any areas that may cause wear or cut the hose. Also
avoid contact with any potential hot surfaces on the appliance.
Be sure that the hose does not create a trip hazard.
Position male swivel fitting on hose assembly to the portable
3.)
LP-Gas appliance female fitting. Connect by turning knurled
section of male swivel fitting clockwise until fully hand tight.
Connect the plastic coupling nut on the hose assembly to the
4.)
large outside threads on the LP-Gas cylinder valve outlet. Hand
tighten the black plastic coupling nut by turning clockwise
until coming to a full stop. Do not cross thread the connection.
Note: this hose assembly is equipped with a QCC-1 appliance
connection and requires a cylinder equipped with a valve
marked for use with a type 1 connection.
WARNING
When leak testing the connections:
Conduct leak test outdoors in a well ventilated area.
•
Do not smoke.
•
Do not use or permit sources of ignition in the area while
•
conducting a leak test.
Do not use matches, lighters or flame to check for leaks.
•
Do not use the appliance until any leaks are corrected.
•
Leak Testing
Before lighting your appliance, check for leaks by applying a
1.)
mild soapy water solution to all connections. Slowly open the
cylinder valve and check for leaks. the appearance of bubbles
indicates a leak.
Repair any leaks prior to lighting your appliance. If you cannot
2.)
stop a leak by additional tightening of the connection, shut off
the LP-Gas supply at the cylinder valve and have an LP-Gas
service person make the needed repairs
Disconnection Guidelines for Hose Assembly
turn burner control knob on portable LP-Gas appliance to “off”
1.)
position. turn LP-Gas “off” at cylinder by turning the cylinder
valve handle fully clockwise.
Disconnect the hose assembly from the LP-Gas cylinder valve
2.)
outlet by turning the plastic coupling nut counter clockwise
until it disengages from the large outside threads on the LP-Gas
cylinder valve outlet.
Disconnect hose from portable LP-Gas appliance assembly by
3.)
turning knurled section of male swivel fitting counter clockwise.
Reinstall the plastic protection cap on the 1"- 20 connection.
4.)
When not in use, store the assembly in a clean and dry area.
5.)
Examine el nuevo conjunto de manguera para verificar que
•
no esté dañado. no use el conjunto de manguera si este se
encuentra dañado. Si estuviera dañado, devuélvalo al lugar
original de compra.
Sólo debe moverse el artefacto a gas, quitarse el conjunto de
•
manguera viejo e instalar un nuevo conjunto de manguera
cuando el artefacto esté frío.
nO
•
use el artefacto hasta que se finalice la prueba de fugas y
se corrija cualquier fuga presente.
Conexión del artefacto
1 pulg.-20
Conexión
del cilindro QCC1
Pautas de instalación para el conjunto de manguera
Gire la perilla del control del quemador del artefacto portátil
1.)
de gas LP a la posición “off” (cerrado). Cierre el pasoe de gas
LP en el cilindro girando la manija de la válvula del cilindro
totalmente hacia la derecha.
Pase la manguera sobre cualquier abertura según sea necesario,
2.)
asegurándose de evitar cualquier área que cause desgaste o
Manguera de extensión de 4 pies
(1.2 m) para artefacto
PELIGRO
Si no se cumplen estas advertencias e instrucciones, se
pueden producir una explosión o un incendio que pueden
causar daños materiales, lesiones personales graves o la
muerte.
NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES
ADVERTENCIA
Para gas LP (propano líquido) únicamente.
•
Para uso únicamente con artefactos que tengan incorporado
•
un sistema de regulación de la presión.
Lea todas las instrucciones antes de instalar y usar.
•
La desconexión de un conjunto de manguera viejo o la
•
instalación de un nuevo conjunto de manguera deben
realizarse al aire libre en un área bien ventilada.
nO
•
modifique este conjunto de manguera. Si el conjunto de
manguera no calza, devuélvalo al lugar de compra original y
obtenga el conjunto de manguera correcto para su artefacto
a gas.
cortes en la manguera. también evite el contacto con cualquier
superficie del artefacto que pueda estar caliente. Asegúrese de
que la manguera no cree un peligro de tropiezo.
Coloque el adaptador giratorio macho del conjunto de la
3.)
manguera en el adaptador hembra del artefacto portátil de gas
LP. Para efectuar la conexión, haga girar la sección estriada
del adaptador giratorio macho hacia la derecha hasta que esté
completamente ajustado a mano.
Conecte la tuerca de acoplamiento de plástico del conjunto
4.)
de la manguera a las roscas externas grandes de la salida de
la válvula del cilindro de gas LP. Ajuste a mano la tuerca de
acoplamiento negro de plástico girándola hacia la derecha hasta
que se detenga. no fuerce la rosca de la conexión. Nota: Este
conjunto de manguera está equipado con una conexión QCC-1
para artefactos y requiere un cilindro equipado con una válvula
marcada para el uso con una conexión tipo 1.
WARNING
Materials used in the construction of this device may
•
contain brass (which may contain lead), a chemical
known to the State of California to cause cancer, birth
defects, or other reproductive harm.
Combustion byproducts produced when using this
•
device contain chemicals known to the State of
California to cause cancer, birth defects or other
reproductive harm.