PROBLEM

POSSIBLE CAUSE AND SOLUTION

Unit will not raise (motor not
running or “humming”).

.

• The emergency stop button may be depressed

or jammed. Check all push-button stations.
Repair as necessary.

• The gate or door is not closed. Check and close.
• The main line disconnect switch is open (off).

Check and close (on).

• The main distribution panel circuit breaker is

tripped or a fuse is blown. Check and reset or
replace as necessary.

• The gate status switch or door interlock is

malfunctioning or is out of tolerance. Check and
repair or adjust as required.

• The main line fuse disconnect fuse is blown.

Check and replace.

• The “UP” push button or circuit is

malfunctioning. Check at the other push button
station for “UP” function. Check components
and circuit. Repair or replace.

• The motor starter overloads (MSO) have tripped.

Check and reset. If it trips again, check for
cause in the motor circuit.

• The control transformer fuse is blown. Check

and replace.

• The motor starter coil (MI) has burned out.

Check and replace. (Will usually blow the control
transformer fuse.)