PROBLEM POSSIBLE

CAUSE AND SOLUTION

Lift raises slowly.

• The structural members of the lift may be binding.

• The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

• The hydraulic line or hose may be leaking.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• Check the oil level in the reservoir.

• The motor voltage/wiring may be incorrect.

• The suction screen may be clogged. Remove and

clean the screen. Drain and replace the oil.

• The suction line may be leaking air due to a loose

fitting. Tighten as needed.

• The breather holes in the reservoir fill plug may be

clogged. Remove and clean.

• The power unit pump may be defective.

Lift lowers slowly.

• The structural members of the lift are binding.

• The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• The return filter may be clogged due to dirt or

damage.