Specifications – Autoquip PLTC DOCK LIFT User Manual
Page 16
16
LOAD CAPACITY
The load capacity rating is stamped on a metal nameplate attached to one side of the
lift. This figure is a net capacity rating for a lift furnished with the standard platform.
The relief valve of the pumping unit has been set to raise the weight, plus a small
amount for overload. Where gravity roll-sections, special tops, etc, are installed on the
lift after leaving the plant, deduct the weight of these from the load rating to obtain the
net capacity.
CAUTION!
Lifts should not be overloaded beyond the established capacity
as damage and/or personal injury may result and will void its
warranty.
DANGER!
Do not make modifications to the lift without authorization
from the manufacturer. Autoquip cannot foresee and is
not responsible for injury or damage which results from
the unauthorized modifications or misuse of the lift.
UNBALANCED LOADING
The stabilization provided is basically for balanced loads. If special attachments extend
beyond the length and/or width dimensions of the platform, the end and/or side load
capacity must be reduced (contact an Autoquip Sales representative).
PUMP PRESSURE
This lift incorporates a positive displacement pump machined to a high degree of
accuracy and specially adapted to requirements of higher-pressure ranges over that of
a standard pump. Therefore, standard factory models of the same manufacture cannot
replace it.
The pump can operate efficiently at intermittent pressures up to 3200 PSI and
continuous duty to 2500 PSI. The safety relief valve in the pump assembly or Deltatrol
Valve is factory-set to stay within the parameters of the pump and lift requirements.
SPECIFICATIONS