Oil requirements, Oil capacity, Every day or 10 hours of operation – Autoquip SERIES 35 SCISSORS LIFT User Manual
Page 29: Every month or 100 hours of operation, Every year or 1000 hours of operation, Notice, 4 oil requirements, 5 oil capacity
29
6.2.4 Oil Requirements
Follow recommendations below that apply to your application.
Environment (Ambient Temperature)
Recommended Oil
Indoor locations with variable temperatures: 30 -
100 degrees F.
5W 30 or 5W 40 Multiviscosity Motor Oil
Indoor locations with constant temperatures: 60
- 80 degrees F.
SAE 20 Motor Oil
Outdoor locations: 30 - 120 degrees F.
5W 30 or 5W 40 Multiviscosity Motor Oil
Outdoor locations: 10 degrees F below 0 to 100
degrees F.
5W 20 or 5W 30 Multiviscosity Motor Oil
Cold Storage Warehouse: 10 - 40 degrees F.
Contact local Autoquip Service Rep.
Note: All oils are detergent type.
Note: Oil level should be 1" to 1-1/2" below the top of the reservoir.
6.2.5 Oil Capacity
Standard Series 35 Polyethylene Tank: Approximately 1.25 gal.
Series 35: 48S80 & 60Sxx Tube Tank: Approximately 2 gal.
Contractor polyethylene Tank: Approximately: 5.5 gal.
Vertical Steel Tank: Approximately: 10 gal.
Use approved fluids only. Use of unauthorized fluids may cause damage
to seals and hosing.
Do Not Use:
• Automatic Transmission Fluid (ATF)
• Hydraulic Jack Oil
• Brake Fluids
NOTICE