• Mode Sheet (continued)
MODE DESCRIPTION PARAMETERS
EXPLANATION
15
Trip 2 Type
Range = 0 - 7
0 - near
1 - exclusive
2 - hysteresis near
3 - far
4 - inclusive
5 - hysteresis far
6 - disable
7 - loss of echo
Default = 0
16
4mA*
Units = Mode 1
Range = 0 - 9999
Default = 3.00
17
20mA*
Units = Mode 1
Range = 0 - 9999
Default = 4.00
18
4mA Trim
Range = 0 - 9999
Default = 5200
19
20mA Trim
Range = 0 - 9999
Default = 9208
20
Offset
Range = 0 - 9999
Default = 0
21
Offset Polarity
Range = neg, pos
Default = neg
22
Calibration
Range = 0 - 9999
Above the
Default = 1
Decimal Point
23
Calibration
Range = 0 - 9999
Below the
Default = 0
Decimal Point
Selects the output type for Trip 2.
Sets the end point for the 4 mA
analog limit.
Sets the end point for the 20 mA
analog limit.
Fine tunes the 4 mA analog output.
(calibrated at the factory)
Fine tunes the 20 mA analog output.
(calibrated at the factory)
Sets an offset for the display.
Selects the direction of the offset.
Add or Subtract the offset from the
distance before displaying.
Sets the integer portion of the
calibration factor.
Sets the fractional portion of the
calibration factor. (decimal point is
assumed, 9999