Mode Sheet (continued)

MODE DESCRIPTION PARAMETERS

EXPLANATION

10

Offset Distance

Range =-999 - +999
Default = 0

11

Temperature

Range = 0 - 2

Compensation

Default = 1

0 = OFF
1 = ON
2 = View/ON

12

Autosense

Range = 0 - 1
Default = 1
0 = OFF
1 = ON

13

Sensitivity

Range = 0 - 100%
Default = 100

14

Blanking

Units = Mode 1
Range = 0.5 to 16 ft.
Default = 1.00

15

Pulses

Units = Pulses
Range = 1 - 20
Default = 16

16

Software
Version

17

Reset

Range = 0 - 1
Default = 0

Sets an offset for the display.

Activates or deactivates internal
Temperature Compensation.

Activates or deactivates AutoSense.

Sets to top sensitivity level. Zero is
the lowest sensitivity settomg and
100 is the highest.

Sets a dead zone in front of the
transducer where echoes are
ignored.

Sets the number of ultrasonic
pulses transmitted in each burst. 20
being the strongest transmit setting.

Displays the Software Version

Resets the mode parameters to their
default values. Entering a 1 will
reset the parameters.