Web guy layout, Staking table – Anchor CENTURY 40 WIDE User Manual
Page 3
![background image](/manuals/554597/3/background.png)
CENTER
POLE
(TYP)
LOOP
SIDE
END
SECTION
SIDE POLE
(TYP)
HOLE
SIDE
END
SECTION
MIDDLE
SECTION
TYP
10’
20’-0”
20’-0”
20’-0”
TYP
10’
20’-0”
20’-0”
40’-0” TENT LINE
60’-0’ TENT LINE
** 72’-1 1/4”
USE DIAGONAL DIMENSION
TO SQUARE LAYOUT
** To find diagonal measurement:
diagonal = width² + length²
1
REQUIRED DISTANCE BETWEEN
SIDE POLES AND STAKE LINES:
7’ POLE STAKE OUT 5’-3”
8’ POLE STAKE OUT 6’-0”
10’ POLE STAKE OUT 7’-6”
WEB GUY LAYOUT *
MARK LOCATION OF STAKES, SIDE POLES & CENTER POLES
3
Staking Table
Illustration
Item No.
Description
Qty. for
40’ x 40’
(2) Ends
Qty. for
20’ Mid
23000
Century Guy
w/ Winch
22
6
37020A
3704242 (over 25)
42” Double
Hd. Stake
66*
18*
33000
2’-0” Stake
Bar w/ (3)
Holes
18
2
33100
4’-0” Stake
Bar w/ (6)
Holes
2
2
23100
Winch Tool
2
0
*
IMPORTANT NOTE: REFER TO CAUTION STATEMENT #2 FOR IMPORTANT WARNING ABOUT NUMBER OF
STAKES SUPPLIED. (SEE BACK PAGE OF THIS MANUAL)
THE INSTALLER MUST USE THE LOCAL SOIL CONDITIONS TO CALCULATE THE ACTUAL
NUMBER OF STAKES REQUIRED AND IS RESPONSIBLE FOR THE STAKING PATTERN AND
CONFIGURATION.
ANCHOR PROVIDES ANCHORING PACKAGES FOR COMMON SOIL CLASSIFICATIONS;
CONTACT YOUR TENT SALES REPRESENTATIVE FOR MORE INFORMATION.
(2) WEB GUYS WITH
4’ STAKE BAR AND (6) 42”
DBL. HEAD STAKE (TYP. AS
SHOWN)
WEB GUY WITH 2’
STAKE BAR AND (3) 42”
STAKES (TYP. AS SHOWN)
SEE STAKING
GUIDELINES ON
NEXT