XONE:4D User Guide

MIXER SECTION — MIX AND MONITOR

1

3

4

5

6

7

8

Mix / Monitor Meters
The main meters follow the selected

monitor source. The meter reads ‘0’ for

an XLR output of +4dBu. The mixer

should be operated with these meters

averaging around ‘0’ with loudest peaks no

higher than ‘+6’.

1

Mix Master Level Control
A rotary master control adjusts the level of

the main mix XLR outputs feeding the house

sound system. This does not affect the mon-

itor output or the meter reading.

3

Monitor Master Level Control
Adjusts the level of the signal to the stereo

monitor RCA output. This does not affect

the headphones. The monitor output could

be used for a booth monitor, recording or

an additional zone feed.

4

Cue Active LED
A large red LED indicator lights when a

channel CUE is active. This indicates that

the selected channel CUE signal is heard in

the headphones and displayed on the

monitor meters.

5

Monitor Select Switches
In the normal ‘up’ position the headphones

and meters monitor the pre-level main mix.

Press these switches to select either of the

stereo FX mixes as the headphones and

meter source. Note that this does not affect

the main mix or monitor outputs.

6

2

Record to FX2 Switch
Selecting this switch will send the pre-fade

mix output to the FX2 Send RCA sockets

on the rear of the mixer.
The mix signal is switched after the

internal FX2 buss, allowing the FX2 Send

controls to still be used for software effect

loops and a source for the BPM counter.