4. Web Management in Device Server
AirLive DS-100 v2 User’s Manual
16
Data Parity
Choose between Even or Odd for error detection, or
select None for no error detection.
Stop Bits
Choose the number of stop bits to be sent at the end of
every character. Electronic devices usually use 1 bit,
slower electromechanical devices use 1.5 bit.
Flow Control
Choose the method of flow control to pause and resume
the transmission of data to coordinate with printer speed.
Select None if flow control is not required.
Network Settings
Static IP Address
The static IP address assigned to DS-100 v2.
Static Subnet Mask
The subnet mask of DS-100 v2.
Static Default Gateway
The default gateway of DS-100 v2.
Static DNS Server
Set the DNS server used by DS-100 v2.
Transmit Timer
TCP transmit timer, set the desired value or use default
value. When the timer expires for a sent packet, sender
will retransmit the packet.
Server Listening Port
Set the port number for communication with the
Gateway/Controller.
Firmware Upgrade
Upgrade firmware from remote-PC via Ethernet.
4.2System Configuration
DS-100 v2 is designed specifically to operate in conjunction with all Gateways/Controllers.
If you are not using default settings, before connecting DS-100 v2 to your
Gateway/Controller, some configurations steps are required. The configuration instructions
for Gateways/Controllers and DS-100 v2 are covered in the following sections.
4.2.1DS-100 v2 Configuration
DS-100 v2 supports web based configuration. By factory default, DS-100 v2 web interface
can be accessed with
IP address: 192.168.1.10
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.254
Step1:
Configure administrator PC’s TCP/IP settings with a static IP address that is under
the same subnet mask as DS-100 v2. For example: 192.168.1.100