Page 18: External power supply, Poe supply

background image

18

2N TELEKOMUNIKACE a.s., www.2n.cz

®

External Power Supply

An external 12 V power supply is connected to terminal block POWER. Use a 12 V ±15
% DC power source dimensioned to current intake of 2 A at least (Part No. 91341481E)
to ensure a reliable function of your device.

PoE Supply

2N

®

Helios IP Uni is compatible with the PoE 802.3af (Class 0 – 12,95 W) technology

and can be supplied directly from the LAN via compatible network elements. If your
LAN in incompatible, insert the PoE injector, Part No. 91758100E, between 2N

®

Helios

and the nearest network element.

IP Uni

Electric Lock Connection

2N®

is equipped with an electrically isolated relay switch with NO and NC

Helios IP Uni

contacts (terminal block RELAY1, up to 30 V / 1 A AC/DC) and 8 up to 12 V
DC depending on power supply (PoE: 9 V; adaptor: power supply voltage minus 2 V),
max 500 mA, switched output (terminal block OUT1), to which a standard electric lock
or another compatible electrical appliance can be connected.

Tamper Switch Connection

2N

®

Helios IP Uni is equipped with a tamper switch for detection of unauthorized

penetration into the device. After correct and complete installation of the device the
tamper switch is closed. Tamper switch opens immediately when the front panel is
removed. Tamper switch contacts are available on terminal block TAMPER SWITCH.

Device Resetting

2N

®

Helios IP Uni is equipped with a RESET button. Push the button for more than

10 s to reset the factory default values, deleting all the data stored in the device. Push