Omega lite installation manual – 2N Omega Series - Instalation Manual User Manual
Page 20

2N
®
- OMEGA Lite
Installation manual
 
Installation manual 
20
5.4. Module 1x external line/1xinternal line with 16 kHz tariff pulse
receivers (order No1880032)
This module is completely identical with the previous one but also contains a 16 kHz 
tariff pulse receiver (T2). The frequency and sensitivity of the receivers are set 
precisely and optimally by the manufacturer. The set sensitivity is approximately -30 
dB. Sensitivity can be reduced by removing jumper J1 to approximately -10 dB. 
Reducing sensitivity would make sense, for example, if tariff pulses were received 
from another line (cross-coupling) or in the case of strong interference (industrial 
converters, high-power TV equipment etc.). The LED on the module indicates the 
receipt of tariff pulses. 
 
 
J1 
- connector for connecting to motherboard (or to extender module 
(connector is secured against incorrect connection by the blanking off 
of PIN 5,6,7,8). 
J2
- connector RJ-45 (PIN 4-5) for connecting analogue external line.
J3
- connector RJ-45 (PIN 4-5) for connecting analogue internal line.
J4
- company servicing reanimation connector (SW for ALTERA).
J5
- connector for setting impedance (1-2= ETSI, 2-3= 600
Ω).
 
 
D1 
- signalling LED (picking up, ringing - external line).
D2
- signalling LED (picking up, ringing – internal line).
 
T1 
-CO transformer.
T2
-16kHz transformer.
 
Note: 
•
Equipment connected to connector J3 (telephone) must comply with the requirements
(standard – type approval) for equipment connected to the unified telephone system.