Full parameter chart 3.2 – 2N Door intercom 2N Helios - Manual, 1322 v3.0 User Manual
Page 48

Full Parameter Chart
3.2
48
971
Count of message
repetitions
0 - 9
3
There is a 3-second pause between
every two messages.
974
Communicator
identification
number
16
digits
-
The number enables communicator
identification.
975
Message options for
automatic multiple
number dialling
2 digits 55
1
st
digit = type of message repeated
after dialling. 2
nd
digit = type of
message after confirmation.
The following digits are used:
2 = identification (974) - loud
speaking
4 = identification (974) - DTMF
5 = message as defined in par. 977
(after confirmation by par. 976)
7 = confirming tone (after
confirmation only)
976
language selection
for a message
0 - 8
1
0 =
1 = English
2 - 3 =
4 = German
5 - 7 =
8 = Portuguese
9 = Dutch
10 ... 99 = silence
Note: See Survey of messages in
Subs. 4.2
Caution! Czech version has language
order: 1 = Czech, 2 = English
977
language selection
for "wait, please"
message
0 - 8
1
991
Service password
12345 12345 by default
995
Software version
identification
-
This function reads out the current
software version. Format: year-
month-day. Writing disable.
997
Deletion of
passwords of all
switches
Service
passwor
d
12345 Deletes passwords 00 and 11 too.
998
Clearing of all
memories
12345 Clears memories 01 to 55.
999
Full initialisation
12345
Warning! Changes the service password
too (setting the default value of 12345).
Notes
Terminology: For the purpose hereof, parameter means a value that is
stored in the 2N
®
Helios memory and can be re-programmed. Function is
a means of execution of another service such as initialisation, software
version identification and so on.
1
) Types 3 and 4 of Automatic Dialling without Confirmation differ from
each other in how they process very short calls (a few seconds). Dialling
type 4 regards a call as successful in all cases, type 3 only if the door was
opened.