2.1.8 Before Using

1. Install battery (not included: use group 22F 300

CCA min), connect positive and ground battery
cables, and check battery condition. Charge if
needed. Note:If needed, a larger group UB72
battery may be used.

Use caution when connecting battery cables near
fuel. A spark could ignite the fuel and cause a fire.

2. Fill the engine with oil (per instructions in supplied

engine manual) and fill the fuel tank with fuel.

Important! See instructions below, for hydrostatic
pump start-up procedure.

2.1.9 Hydraulic Fluids

Handle pressurized hydraulic fluid carefully.
Escaping pressurized hydraulic fluid can have

sufficient force to penetrate your skin causing serious
injury. This fluid may also be hot enough to burn.
Serious infection or reactions can develop if proper
medical treatment is not administered immediately.

Premium hydraulic fluids containing high quality rust,
oxidation, and foam inhibitors are required. These
include premium turbine oils, API CD engine oils per
SAE J183, M2C33F or G automatic transmission fluids
meeting Allison C-3 or Caterpillar TO-2, and certain
specialty agricultural tractor fluids.

2.1.10 Prepare Hydraulic System

Follow this start-up procedure when starting a new
installation or when restarting an installation in which
the hydrostatic pump has been removed from the system.

The flow from the reservoir to the hydrostatic pump and
the flow returning from the hydrostatic pump are always
the same. Hydraulic fluid can flow either direction
between the hydrostatic pump, crossover relief valve,
and motor. Refer to page 21 for the hydraulic Schematic.

1. Before starting the hydrostatic pump, make sure all

system components (reservoir, fittings, etc.) are clean.

2. Fill the reservoir with recommended hydraulic

fluid, which should be filtered before entering the
reservoir.

3. The inlet line leading from the reservoir to the

charge pump must be filled before start-up. Loosen
the fitting at the pump on this inlet line until oil
bleeds out.

Hydrostatic pressure controlled by the crossover relief
valve is factory set at 1750 PSI. A 2000 PSI shim kit is
available for extreme conditions.

Figure 2.7 Pump-Component Locations

Warning! Do not start engine unless pump is in
neutral or detent position on the cable.

4. Start the engine and run at the lowest possible

RPM.

5. Loosen the motor fittings until oil bleeds out to

remove air from the system. Retighten fittings.

6. As air is purged from the unit, the oil level in the

reservoir will drop and bubbles may appear in the
fluid. Refill the reservoir as necessary.

6. Run the feed roller in both directions for several

minutes until any remaining air is purged from the
unit. Refill the reservoir as necessary.

8. Shut down the engine, check for and correct any

fluid leaks, and check the reservoir level. Add fluid
if necessary. The hydrostatic pump is now ready for
operation.