PTO CHIPPERS

22

Section

TROUBLESHOOTING

6

6.1 FLASH CODE GUIDE FOR THE CONTROLLER

GUIDE TO THE CONTROLLER FLASH CODES

SIGNAL

FREQUENCY

CAUSE

ACTION TO TAKE

GREEN

GREEN

SOLID

Chipper has reached default chipping

RPM and forward feed is available.

Machine available for standard use.

GREEN

"½ second on,

½ second off"

Chipper has not reached chipping RPM

upon initial startup.

Slowly increase RPM.

GREEN

"½ second on,

½ second off"

Chipper RPM dropped while chipping.

Feed roller will automatically reverse

to bring RPM back up.

RED

RED

"½ second on,

½ second off"

Feed bar not in NEUTRAL upon initial

startup.

Place feed bar in NEUTRAL.

RED

SOLID

Safety bar was activated and forward coil

or reverse coil faults are not active.

Push Safety Bar Reset/Override

Switch.

RED

FLASHING

Machine has been below operational

RPM for more than 10 minutes.

10 minute timer is a safety feature

and will require the safety bar to be

returned to NEUTRAL position before

operation can resume.

AMBER

AMBER

"2 seconds on,

2 seconds off"

Blade service code is active, feed bar

was placed in NEUTRAL after power up

and the control system has not detected

chipper RPM.

Service blades. Reset code by turning

key on and shift the feed bar from

REVERSE to REVERSE then back

3 times. This must be done within 60

seconds of turning key on and the

engine cannot be running.

AMBER

Solid for 7

seconds, then a

long pause, then

repeat

Forward infeed coil fault. If active all

other codes are ignored.

Test wiring to forward coil. Replace

coil if out of specification.

AMBER

"½ second on,

½ second off"

Reverse coil fault. If active all other

codes are ignored.

Test wiring to reverse coil. Replace

coil if out of specification.

This manual is related to the following products: