Daily inspection, See figure 5-3.), 3 rug carrier accessory – JLG 15VPSP Operator Manual User Manual
Page 43: General (see figure 5-4. & figure 5-5.), Rug carrier accessory -3, Daily check of operation - transducer arrays -3

SECTION 5 - OPTIONAL EQUIPMENT
3120796
– JLG Lift –
5-3
Daily Inspection
(See Figure 5-3.)
From ground controls, raise platform approximately 5’-6’.
The red LED on the electronic module will be illuminated
when power is applied. If an obstruction, such as a pad of
paper is placed under one of the transducer sensor
arrays, the LED will flash and remain flashing while the
obstruction is present and stop flashing 3 seconds after
the obstruction is removed. Check the operation of all
transducer sensor arrays by placing an object sequen-
tially under each sensor array (within approximately 6"-12")
and checking if the LED starts to "flash", and stops flash-
ing 3 seconds after the obstruction is removed. Also,
inspect the transducer arrays and electronic module for
physical damage, loose wires, loose mounting hardware,
etc.
NOTE: If the OSS malfunctions or operates improperly, con-
tact JLG Industries, Inc., Customer Support for fur-
ther evaluation.
5.3
RUG CARRIER ACCESSORY
NOTE: The Rug Carrier accessory is available only on the
JLG model 15VPSP and not authorized for use with
any other JLG lift. The Rug Carrier Accessory is
intended for use in hanging and removal of rugs in
hanging display racks only. Use for any other pur-
pose is not authorized by JLG.
General
(See Figure 5-4. & Figure 5-5.)
The Rug Carrier Accessory consists of two pivoting arms
mounted to the 15VPSP platform left side rails. The pivot-
ing arms are locked in the plane of the platform side rail
when not in use (the stowed position). The arms are
locked into position at approximately 90 degrees to the
left side platform side rails when in use (the carry posi-
tion). The pivoting arms’ position can be changed by lift-
ing each arm to release the lock, rotating the arm, and
lowering each arm back into a locked position.
Figure 5-3. Daily Check of Operation - Transducer Arrays.
LED
LOCATED
ON OSS
ELECTRONIC
MODULE
(Beneath
Decal
Billboard)
DETECTION
ZONE
HOLD
6 to 12 IN.
(
FROM
EACH
TRANSDUCER
ARRAY
15 TO 30 CM)
PAD OF
PAPER
OR
SIMILAR
SIZE
OBJECT