Fig. 11—unit wiring diagram – Bryant 330JAV User Manual

Page 8

background image

Fig. 11—Unit Wiring Diagram

A01365

LEGEND

ALS1

AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)

ALS2

AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)

BHI / LOR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BHT / CLR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLWM

BLOWER MOTOR, 4 or 5 -SPEED, PERMANENT-SPLIT-CAPACITOR

BLWR

BLOWER MOTOR RELAY, SPST (N.O.)

CAP

CAPACITOR

CPU

MICROPROCESSOR AND CIRCUITRY

DSS

DRAFT SAFEGUARD SWITCH (N.C.)

EAC-1

ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)

EAC-2

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FRS1

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FRS2

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FSE

FLAME-PROVING SENSOR ELECTRODE

FU1

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED

FU2

FUSE, FIELD INSTALLED

GV

GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE

HPS

HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)

HPSR

HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)

HSI

HOT-SURFACE IGNITER (115 VAC)

HSIR

HOT-SURFACE IGNITOR RELAY, SPST (N.O.)

HUM

24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)

IDM

INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE

IDR

INDUCER MOTOR RELAY, SPST (N.O.)

IHI / LOR

INDUCER MOTOR SPEED CHANGE RELAY, SPDT

ILK

BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)

JB

JUNCTION BOX

LED

LIGHT-EMITTING DIODE FOR STATUS CODES

LGPS

LOW GAS-PRESSURE SWITCH, SPST (N.O.)

LPS

LOW-HEAT PRESSURE SWITCH, SPST (N.O.)

LS

LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)

MGVR

MAIN GAS VALVE RELAY, DPST (N.O.)

-

1 = VALVE

-

2 = HUMIDIFIER

PL1

12-CIRCUIT CONNECTOR

PL2

9-CIRCUIT CONNECTOR

PL3

3-CIRCUIT IDM CONNECTOR

PL6

2-CIRCUIT HSI CONNECTOR

SW1

HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)

*

SW2

LOW-HEAT-ONLY SWITCH, SPST (MANUAL)

*

SW3 & 4

BLOWER-OFF DELAY SETTING SWITCHES,
SPST (MANUAL)

*

TJ

TWINNING JUMPER, SPDT FOR MAIN OR
SECONDARY STATUS (MANUAL CHANGE OVER)

TRAN

TRANSFORMER-115VAC/24VAC

TWIN/TEST

1-CIRCUIT TWINNING BUSS CONNECTOR,

ALSO STATUS CODE RECALL

JUNCTION

TERMINAL

CONTROL TERMINAL

FACTORY POWER WIRING (115VAC)

FACTORY CONTROL WIRING (24VAC)

FIELD POWER WIRING (115VAC)

FIELD CONTROL WIRING (24VAC)

CONDUCTOR ON CONTROL

FIELD WIRING SCREW TERMINAL

FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

NOTES:

1. Use only copper wire between the disconnect switch and

the unit.

2. If any of the original wire, as supplied, must be replaced,

use the same or equivalent type wire.

3. Inducer (IDM) and blower (BLWM) motors contain

internal auto-reset thermal overload switches.

4. Blower motor speed selections are for average

conditions. See Installation Instructions for details on
optimum speed selection.

5. Replace only with a 3-AMP fuse.
6. Auxiliary limit switches (ALS1 & 2) used on some

horizontal and some downflow models.

7. This wire must be connected to furnace sheet metal for

control to prove flame.

8. Factory connected when LGPS not used.

RED

LS

FRS2

FRS1

(WHEN USED)

ALS1

DSS

OR

N

LGPS

YEL

NOTE #8

LPS

NO

T

E

#

8

(W

H

E

N US

E

D

)

(WHEN USED)

NOTE #6

ALS2

SWITCH

1

2

HEAT
SET-UP
SWITCH
NORM
HI HT
LO HT

*

ON

OF

F

OF

F

ON

BLOWER-
OFF DELAY
(SEC.)

SWITCH

3

4

90 SEC

135 SEC

*

180 SEC
225 SEC

ON

OF

F

OF

F

ON

2-STAGE

FURNACE

CONTROL

FA

C

T

O

R

Y

S

E

TTI

NG

S

1

2

34

ON

OF

F

3

2

1

BL

U

BLOWER-OFF DELAY
BLOWER-OFF DELAY
LOW-HEAT ONLY
HIGH-HEAT ONLY

*

W2

Com
24V

W/W1 Y/Y2

R

G

HUM

LED

S

M

TJ

TWIN

TEST

12

11

1

0

P1

WHT

32

1

9

87

FS

E

HPS

HI

P

M

IDM

HSI

ILK

JB

L1

PL6

1

2

1

2

3

PL3

PL2

PR1

PR2

L1

L2

COMMON

HI-COOL

HI-GAS

HEAT

EAC-2

EAC-1

LO-GAS

HEAT

SPARE

SEC1

FU1

SEC2

NOTE #4

BLWM

BRN

BRN

CAP

TRAN

GV

C

FUSED DISCONNECT

SWITCH (WHEN REQ’D)

NOTE #1

BLK

WHT

GND

L2

FU2

CONNECTION DIAGRAM

L1

BLWR

TO 115VAC FIELD
DISCONNECT SWITCH

NOTE #1

LO-GAS-HEAT

HI-GAS-HEAT

SPARE

NOTE #4

COMMON

HSIR

EAC-1

EAC-2

3

1

HSI

2

9

PL2

PR2

115VAC

PR1

TRAN

24VAC

IDR

L2

ILK

IDM

BLWM

BHI / LOR

BHT / CLR

CAP

BRN

BRN

PL6

IHI / LOR

SEC1

FU1

NOTE #5

1

2

3

HI

COM

HPSR

1
5
6

2

N/A

N/A

HI-COOL

PL3

4

7

SEC2

8

LS

ALS1

DSS

ALS2

FRS1

(WHEN USED)

FRS2

N/A

12

2

3

MGVR-2

9

6

NOTE #8 LPS

(WHEN USED)

TWIN
TEST

S

M

W/W1

R

HUM

TWINNING
JUMPER
TJ

W2

Y/Y2

G

MGVR-1

NOTE #8

HPS

5

4

1

10

7
8 N/A

N/A

FSE

11

HI

M

P

C

NOTE#7

PL1

CPU

LGPS

LO

SW1

GV

OR

N

SW

4

SW

3

SW

2

C

OM

9. Symbols are an electrical representation only.
10. BLOWER-ON DELAY: Gas heating 45 seconds,

Cooling/Heat Pump 2 seconds.

11. Cooling/Heat Pump BLOWER-OFF DELAY is 90

seconds.

12. IGNITION-LOCKOUT will occur after four

consecutive unsuccessful trials-for-ignition.
Control will automatically reset after three hours.

13. Control must be grounded at pin 10 of 12-pin

connector.

14. NA - Not Applicable
15. Spare terminal and wire not available on some

applications. Insulate connector if not available.

RED

LO

RED

MED LO

BLU

COM

WHT

BLK

HI

YEL

MED HI

MED

COM

HI

MED

MED LO

LO

NOTE #15

ORN

SPARE

MED HI

SPARE

BLU

NOTE #15

324459-101 REV. D

WH

T

BL

K

BLU

BRN

GRY

BRN

GR

Y

WHT

WHT

RE

D

WHT

WHT

BLK

RED

BL

K

YEL

YEL

BR

N

GR

Y

BLU

ORN

ORN

ORN

RE

D

RE

D

RE

D

WHT

BLK

BLK

BLK

BLK

WHT

BL

U

RE

D

RED

RED

(NATURAL GAS & PROPANE)

SCHEMATIC DIAGRAM

EQUIPMENT
GROUND

GR

N

/YEL

GR

N

/Y

E

L

GRN/YEL

GRN/YEL

GRN/YEL


8