f. Rinse and let dry. Oiling or coating of filters is not

recommended or required.

g. Reinstall filters.

h. Replace blower access door and turn on electrical supply

to furnace.

2. Upflow/Horizontal–filters installed in media cabinet adja-

cent to furnace (See Fig. 5.)

a. Turn off electrical supply to furnace

b. Remove filter cabinet door.

c. Slide filter out of cabinet.

d. If equipped with permanent, washable filter, clean filter

by spraying cold tap water through filter in opposite
direction of airflow. Rinse filter and let dry. Oiling or
coating of the filter is not recommended.

e. If equipped with factory-specified disposable media

filter, replace only with media filter having the same part
number and size.

f. Slide filter into cabinet.

g. Replace filter cabinet door.

h. Turn on electrical supply to furnace.

3. Upflow/Horizontal–filter(s) installed in side(s) and/or bot-

tom of blower compartment (See Fig. 5.)

a. Turn off electrical supply before removing blower and

control access doors.

b. Release filter retainer from clip at front of furnace

casing. (See Fig. 5.) For side return, clips may be used
on either or both sides of the furnace.

c. Slide filter out.

d. Clean filters by spraying tap water through filter from

opposite direction of airflow.

e. Rinse and let dry. Oiling or coating of filter is not

recommended or required.

f. Place filter in furnace.

g. Replace blower and control access doors and turn on

electrical supply to furnace.

II.

BLOWER MOTOR AND WHEEL

The following items should be performed by a qualified service
technician:

For long life, economy, and high efficiency, clean accumulated dirt
and grease from blower wheel and motor annually.

The inducer and blower motors are pre-lubricated and require no
additional lubrication. These motors can be identified by the
absence of oil ports on each end of the motor.

Clean blower motor and wheel as follows:

1. Turn off electrical supply to furnace.

2. Remove blower access door.

3. Downflow only:

a. Disconnect vent connector from furnace flue collar. (See

Fig. 6.)

b. Remove internal vent pipe enclosure cover.

c. Disconnect and remove short piece of vent pipe from

within furnace.

d. Disconnect and remove vent pipe enclosure. Push bot-

tom side backward to release tabs.

NOTE:

Vent pipe is SCREWED and RTV sealed to relief box.

4. Disconnect blower leads from furnace control. Note wire

color and location for reassembly. Also, disconnect auxil-
iary limit switch leads (downflow only, if present).
All other factory wires can be left connected, but field
thermostat connections may need to be disconnected de-
pending on their length and routing.

5. Remove 2 screws securing control and transformer support

to furnace.

6. Hang control and transformer support to front of furnace

casing.

Fig. 4—Downflow Filter Arrangement

A88486

RETURN-AIR

PLENUM

;;;;

;;;;

;;;;

;;;;

;;;;

;;;;

;;;;

;;;;

;;;;

AIRFLOW

ACCESS DOOR

INSTALLATION

POSITION

OF FILTERS

Fig. 5—Model 330JAV Upflow

A00293

BLOCKED
VENT
SAFEGUARD

FLUE
COLLECTOR
BOX

MOUNTING

SCREWS

RELIEF

BOX

CONTROL

FILTER
RETAINER

WASHABLE
FILTER
FURNACE

FLUE
COLLAR

PRESSURE
SWITCH

GAS

VALVE

C

OM

24V

HUM

HUM

G

R

Y

W

WASHABLE
FILTER OR
DISPOSIBLE
MEDIA FILTER
IN FILTER
CABINET

—3—