2210 TRIGGER CLOSED TOO LONG WHILE IN
NEUTRAL
The trigger switch was closed for more
than five seconds while the joystick was
centered.
• Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2232 FUNCTION PROBLEM - DRIVE & LIFT
BOTH OPEN
The drive and lift inputs are both de-ener-
gized in platform mode.
• Check if either function is active, if Yes;
Refer problem to a qualified JLG mechanic.
2-3 Ground Controls
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
231
FUNCTION PROBLEM - LIFT PERMA-
NENTLY SELECTED
The ground control box lift switch was
closed up or down, during power-up in
ground mode.
• Check if the lift switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
232
GROUND LIFT UP / DOWN ACTIVE
TOGETHER
The lift up / down inputs are closed simul-
taneously.
• Check if the lift switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
233
FUNCTION PROBLEM - BRAKE RELEASE
PERMANENTLY SELECTED
The manual brake release switch was
closed during power-up.
• Check if the brake release switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.