1 tilt sensor, 1 tilt sensor -32, 7 electric motor – JLG 3246ES Operator Manual User Manual
Page 83

SECTION 4 - MACHINE OPERATION
3121165
– JLG Lift –
4-33
7710 PUMP P HIGH - CHECK POWER CIR-
CUITS
The power module detected a problem in
the drive motors' power circuit wiring.
Refer problem to a qualified JLG mechanic.
7711 PUMP P LOW - CHECK POWER CIR-
CUITS
The power module detected a problem in
the drive motors' power circuit wiring.
Refer problem to a qualified JLG mechanic.
7741 ARMATURE BRAKING CURRENT TOO
HIGH
The power module has detected excessive
braking current .
This can be caused by transporting an excessive load on a steep grade.
7742 FIELD VOLTAGE IMPROPER
The power module detected a problem in
the drive motors' power circuit wiring.
Recycle power on/off, if problem persists;
Refer problem to a qualified JLG mechanic.
7-7 Electric Motor
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
8-1 Tilt Sensor
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
811
TILT SENSOR NOT CALIBRATED
The tilt sensor calibration has not been
performed.
Refer problem to a qualified JLG mechanic.
812
NO DATA FROM TILT SENSOR - NOT
CONNECTED OR FAULTY
No signal from tilt sensor.
Refer problem to a qualified JLG mechanic.