2 platform controls, 2 platform controls -21 – JLG 3246ES Operator Manual User Manual
Page 72

SECTION 4 - MACHINE OPERATION
4-22
– JLG Lift –
3121165
2-2 Platform Controls
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
221
FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED
The horn switch was closed during power-
up in platform mode.
• Check if the horn switch is damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.
222
FUNCTION PROBLEM - INDOOR / OUT-
DOOR PERMANENTLY SELECTED
The indoor / outdoor (zone A / zone B)
switch was closed during power-up in plat-
form mode.
• Check if the indoor/outdoor (zone A / zone B) capacity switch is damaged,
obstructed or jammed.
Refer problem to a qualified JLG mechanic.
223
FUNCTION PROBLEM - DRIVE & LIFT
ACTIVE TOGETHER
The drive and lift inputs are closed simulta-
neously in platform mode.
• Check drive/lift switch for visible damage.
Refer problem to a qualified JLG mechanic.
224
FUNCTION PROBLEM - STEER LEFT
PERMANENTLY SELECTED
The steer left switch was closed during
power-up in platform mode.
• Check if the steer left switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
225
FUNCTION PROBLEM - STEER RIGHT
PERMANENTLY SELECTED
The steer right switch was closed during
power-up in platform mode.
• Check if the steer right switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
226
ACCELERATOR FAULTY - WIPER OUT OF
RANGE
There is a problem with the joystick.
• Center joystick and check to see if a power cycle will clear DTC.
Refer problem to a qualified JLG mechanic.
227
STEER SWITCHES FAULTY
The steer left and steer right inputs were
closed simultaneously.
• Check if the steer switches are damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.
228
FUNCTION LOCKED OUT - ACCELERA-
TOR NOT CENTERED
The joystick was not centered at power-up. • Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
229
FUNCTION PROBLEM - TRIGGER PER-
MANENTLY CLOSED
The trigger switch was closed during
power-up in platform mode.
• Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.