Table 6-11. Battery Charger Fault Codes
CODE
DESCRIPTION
STATUS
ACTION
8
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
13
Communication pro.blem with external memory.
Battery charger stops working.
Contact service dept. or change product.
18
Extended shutdown or power failure.
Battery charger stops supplying power. Operation 
resumes as soon as alarm conditions are no longer 
present or after restarting. 
If problem is a power failure, check battery charger 
mains power supply. 
19
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
240
Digital input is open and managed as hardware 
start-stop. 
Battery charger stops charging until digital input 
closes. 
Close digital input.
241
Problem in CANBUS communication with other sys-
tems in the network. 
The way this is managed may change based on dif-
ferent firmware releases. 
Check correct operation of CANBUS system.
242
Error when reading internal memory on microcon-
troller. 
Battery charger stops working.
Contact service dept. or change product.
244
Mains voltage lower than maximum operating 
range tolerance.
Battery charger won’t start charging until mains 
voltage returns within normal operating range.
Make sure mains voltage is within correct operating 
parameters.
245
Abnormal current draw in primary section.
Battery charger stops supplying power. Operation 
resumes as soon as alarm conditions are no longer 
present. 
If problem persists, contact service dept. or change 
product.