Chapter 6 – Controls
26
TB80/TB85J Fixed Axle – 0112823EE
Dual Fuel
Engines on machines with the dual fuel option can be
operated using gasoline or liquefied petroleum gas (LPG).
Dual fuel machines have a gasoline tank behind the door
on the right side of the turntable and an LPG tank at the
rear of the turntable.
The dual fuel switch to select between gasoline and LPG
operation is on the lower control panel.
Place the switch up to operate the engine using gasoline
and down to operate the engine using LPG.
Driving and Platform Work Lights
The control for the optional driving and tail lights is on the
right side of the upper control panel (refer to Figure 6.7).
Place the switch in the on position to operate the driving
lights. There is also an individual light control on the back
of each light (refer to Figure 6.10).
Figure 6.10 – Platform Work Light
The control for the optional platform work lights is on the
back of each light.
Platform Foot Switch
The upper controls are interlocked through the platform
foot switch (refer to Figure 6.8). Step down on and hold
the platform foot switch to activate the drive and boom
functions from the upper controls.
Figure 6.8 – Platform
Machine/Generator Switch
The switch for the optional AC generator is located on the
front of the upper control panel (refer to Figure 6.9).
Figure 6.9 – Platform Work Light
With the engine running, place the switch in the genera-
tor position to provide electrical power to the electrical
outlet at the platform. Place the switch in the machine
position to turn off the generator and resume machine
operation.
Machine functions will not operate while the switch is in
the generator position.
Light Switch
Machine/Generator Switch
Platform Foot
Switch