Warning, Chapter 4 – safety devices – Snorkel TB85J Fixed Axle CE User Manual
Page 19
TB80/TB85J Fixed Axle – 0112823EE
15
This aerial work platform is manufactured with safety de-
vices, placards, and decals to reduce the likelihood of an
accident. For the safety of all personnel, do not disable,
modify, or ignore any safety device. Safety devices are
included in the daily prestart inspection.
A
Warning
The potential for an accident increases when safety
devices do not function properly. Death or serious
injury can result from such accidents. Do not alter,
disable, or override any safety device.
If any safety devices are defective, remove the aerial plat-
form from service until qualified maintenance personnel
can make repairs.
Emergency Stop Controls
There is an emergency stop control at the lower and up-
per controls.
At the lower controls, the emergency stop is a two-posi-
tion push button (refer to Figure 4.1). Push the emer-
gency stop button in to disconnect power to all control
circuits. Pull the button out to restore power.
Figure 4.1 – Lower Controls
Note
The lower controls override the upper controls. If the up-
per control emergency stop button is engaged, the lower
controls can still be used to operate the aerial platform.
At the upper controls, the emergency stop is a two-posi-
tion push button (refer to Figure 4.2).
Chapter 4 – Safety Devices
Figure 4.2 – Upper Controls
Push the emergency stop button in to disconnect power
to the upper control circuits. Pull the button out to re-
store power.
Emergency Power System
The emergency power system includes a back-up pump,
motor, and battery. Use this system to operate the boom
and turntable functions to lower the platform if the main
power system fails due to engine or pump failure.
Hold the emergency power switch (refer to Figure 4.1
and 4.2) down to activate the emergency power system.
The length of time the pump can be operated depends on
the capacity of the battery.
Emergency Lowering Knob
The emergency lowering knob may be used to lower the
booms if the engine will not start and the emergency
power system will not work. The knob is on the base end
of the main boom lift cylinder (refer to Figure 4.3) under
the left side of the turntable.
Figure 4.3 – Emergency Lowering Knob
The knob may be turned to open the cylinder bleed down
valve for emergency lowering.
Emergency
Lowering Knob
Emergency
Stop Button
Engine/Emergency
Power Switch
Emergency
Stop Button
Ground
Operation Switch
Engine/Emergency
Power Switch