Chapter 7 – Prestart Inspection

26

SR3084SL – 8210037

Weldments

To inspect the weldments:

1. Visually inspect all weldments for abnormal wear,

abrasion, or deformation that could cause interfer-

ence between moving parts.

2. Inspect the welds on the structural components. Pay

particular attention to arm welds around pin bosses.

The area to be inspected should be clean and free

of dirt and grease.

3. Look for visible cracks in the welds and at the weld

to parent material joints. A bright light may be used

to provide adequate visibility of the inspection area.

Fasteners

To inspect the fasteners:

1. Visually inspect all fasteners to see that none are

missing or loose.

2. Inspect all of the bolts, nuts, rollpins, collars, and

snap rings that connect the elevating assembly. They

should all be present, tight, and not damaged in any

way.

Upper Control Station

Inspect the platform and upper controls only if all functions

operated properly from the lower controls.

Guardrail System

The guardrail system includes (refer to Figure 7.11):

A top rail

A mid rail

An entry gate

Toeboards around the sides of the platform.

Figure 7.11 – Platform

To inspect the guardrail system:

1. Inspect all components of the guardrail system. The

rails and toeboards must all be in place and free of

any damage or deformation.

y
y
y
y

Entry

Gate

Top Rail

Toeboard

Mid Rail

Entry

Gate

Top Rail

Toeboard

Mid Rail

Upper Controls Emergency Stop Override

The upper controls emergency stop override allows

the platform to be lowered from the lower controls in

the event the upper controls emergency stop button is

depressed.

Use the following procedure to test the upper controls

emergency stop override:

1. At the upper controls, press the emergency stop

button inward.

2. At the lower controls, turn the on/off switch to the on

position and twist the emergency stop button clock-

wise.

3. Hold the upper controls emergency stop override

switch upward to active the lower controls, and press

the start button to start the engine.

4. While holding the upper controls emergency stop

override switch upward, test the operation of the

lower controls.

Lowering Alarm

The machine is equipped with a lowering alarm. Lower

the platform to ensure that the alarm sounds to warn
personnel in the area to stand clear.

All Motion Alarm

The machine may be equipped with an all motion

alarm.

Operate the machine functions to ensure that the alarm

sounds to warn personnel in the area that the aerial
platform is in motion.

Flashing Light

The machine may be equipped with an optional fl ashing

light mounted to the machine.

To inspect the fl ashing light:

1. At the lower controls, turn the on/off switch to the on

position and twist the emergency stop button clock-

wise.

2. Visually check to see that the light is fl ashing ap-

proximately one fl ash per second.

Note
There is not an off switch for the fl ashing light. The light
cannot be turned off while the engine is running.

Structures

Visually inspect all weldments and related components.

It is important to inspect the fasteners that connect the

components.