Snorkel SR3084SL User Manual
Page 30

Chapter 7 – Prestart Inspection
26
SR3084SL – 8210037
Weldments
To inspect the weldments:
1. Visually inspect all weldments for abnormal wear,
abrasion, or deformation that could cause interfer-
ence between moving parts.
2. Inspect the welds on the structural components. Pay
particular attention to arm welds around pin bosses.
The area to be inspected should be clean and free
of dirt and grease.
3. Look for visible cracks in the welds and at the weld
to parent material joints. A bright light may be used
to provide adequate visibility of the inspection area.
Fasteners
To inspect the fasteners:
1. Visually inspect all fasteners to see that none are
missing or loose.
2. Inspect all of the bolts, nuts, rollpins, collars, and
snap rings that connect the elevating assembly. They
should all be present, tight, and not damaged in any
way.
Upper Control Station
Inspect the platform and upper controls only if all functions
operated properly from the lower controls.
Guardrail System
The guardrail system includes (refer to Figure 7.11):
A top rail
A mid rail
An entry gate
Toeboards around the sides of the platform.
Figure 7.11 – Platform
To inspect the guardrail system:
1. Inspect all components of the guardrail system. The
rails and toeboards must all be in place and free of
any damage or deformation.
y
y
y
y
Entry
Gate
Top Rail
Toeboard
Mid Rail
Entry
Gate
Top Rail
Toeboard
Mid Rail
Upper Controls Emergency Stop Override
The upper controls emergency stop override allows
the platform to be lowered from the lower controls in
the event the upper controls emergency stop button is
depressed.
Use the following procedure to test the upper controls
emergency stop override:
1. At the upper controls, press the emergency stop
button inward.
2. At the lower controls, turn the on/off switch to the on
position and twist the emergency stop button clock-
wise.
3. Hold the upper controls emergency stop override
switch upward to active the lower controls, and press
the start button to start the engine.
4. While holding the upper controls emergency stop
override switch upward, test the operation of the
lower controls.
Lowering Alarm
The machine is equipped with a lowering alarm. Lower
the platform to ensure that the alarm sounds to warn
personnel in the area to stand clear.
All Motion Alarm
The machine may be equipped with an all motion
alarm.
Operate the machine functions to ensure that the alarm
sounds to warn personnel in the area that the aerial
platform is in motion.
Flashing Light
The machine may be equipped with an optional fl ashing
light mounted to the machine.
To inspect the fl ashing light:
1. At the lower controls, turn the on/off switch to the on
position and twist the emergency stop button clock-
wise.
2. Visually check to see that the light is fl ashing ap-
proximately one fl ash per second.
Note
There is not an off switch for the fl ashing light. The light
cannot be turned off while the engine is running.
Structures
Visually inspect all weldments and related components.
It is important to inspect the fasteners that connect the
components.