beautypg.com

Danger, Caution, Chapter 7 – controls – Snorkel S3246 CE User Manual

Page 23

background image

S2646/S3246 – 0410063EE

19

Figure 7.2 – Lower Controls

Emergency Stop Button
The emergency stop is a two-position push button. Push
the button in to disconnect power to all control circuits.
Pull the button out to restore power.

Control Selector Switch
Insert the key into the control selector switch. Turn the
switch to the lower controls position to operate aerial
platform functions from the lower controls. The upper con-
trols will not operate while the control selector is in the
lower position.

Turn the switch to the upper controls position to operate
the aerial platform functions from the upper controls.

In the center position, aerial platform functions will not
operate from the lower or upper controls.

Platform Raise/Lower Switch
Pull up on the platform switch toward the white arrow to
raise the platform. Release the switch when the desired
height is reached.

Push down on the switch toward the black arrow to lower
the platform. The lowering alarm will sound as the plat-
form lowers.

Upper Controls

The upper controls (refer to Figure 7.3) are located on the
control box at the platform. The following controls are
located at the upper control station.

• Emergency stop button
• Drive/lift selector switch
• Drive range switch
• Joystick to control platform lift, drive and steer

The horn button and battery condition indicator gauge
may also be located at the upper control station.

A

Danger

Pinch points may exist between moving compo-
nents. Death or serious injury can result from be-
coming trapped between components, buildings,
structures, or other obstacles. Make sure all person-
nel stand clear while operating the aerial platform.

Controls to position the platform are located on the lower
control panel on the chassis and on the upper control
panel in the platform. Drive controls are located on the
upper control panel only.

Battery Disconnect Switch

The battery disconnect is located next to the latch on the
battery tray (refer to Figure 7.1).

Figure 7.1 – Battery Disconnect Switch

The battery disconnect switch removes electrical power
from all electrically controlled functions when in the off
position. Place the switch in the on position to operate
any electrically controlled function.

A

Caution

Only authorized personnel should operate the aerial
platform. Unqualified personnel may cause injury
to coworkers or property damage. Lock the battery
disconnect switch in the off position before leaving
the aerial platform unattended.

Lock the battery disconnect switch in the off position to
prevent unauthorized use of the aerial platform.

Lower Controls

The lower controls (refer to Figure 7.2) are located on the
right side of the chassis. Only platform functions can be
operated from the lower controls. The following controls
are located on the lower control panel.

• Emergency stop button
• Control selector switch
• Platform raise/lower switch

Chapter 7 – Controls

Battery Disconnect Switch

Emergency
Stop Button

Platform Raise/Lower Switch

Control Selector Switch

This manual is related to the following products: