Battery Charging
Charge batteries at end of each work shift or
sooner if batteries have been discharged.
Charge batteries in a well ventilated area.
Do not charge batteries when the work
platform is in an area containing sparks or
flames.
Permanent damage to batteries will result if
batteries are not immediately recharged
after discharging.
Never leave charger operating unattended
for more than two days.
Never disconnect cables from batteries
when charger is operating.
Keep charger dry.
1. Check battery fluid level (Figure 7). If electro-
lyte level is lower than 3/8 in. (10 mm) above
plates add distilled water only.
2. Connect extension cord (12 gauge (1.5 mm²)
conductor minimum and 50 ft. (15 m) in length
maximum) to the charger outlet plug located at
the rear of the machine. Connect other end of
extension cord to properly grounded outlet of
proper voltage and frequency.
3. Charger turns on automatically after a short
delay, the ammeter will indicate DC charging
current.
4. Charger turns off automatically when batteries
are fully charged.
Battery Maintenance
Hazard of explosive gas mixture. Keep
sparks, flame and smoking materials away
from batteries.
Always wear safety glasses when working
with batteries.
Battery fluid is highly corrosive. Rinse
away any spilled fluid thoroughly with clean
water.
Always replace batteries with UpRight
batteries or manufacturer approved re-
placements weighing 62 lbs. each.
Check battery fluid level daily (Figure 7), especially
if work platform is being used in a warm, dry
climate.
If electrolyte level is lower than 3/8 in. above
plates add distilled water only. DO NOT use tap
water with high mineral content it will shorten
battery life.
Keep terminals and tops of batteries clean.
Refer to the Service Manual to extend battery life
and for complete service instructions.
Figure 7: Battery Charger
Figure 8: Battery Module
Battery Charger
Charger Plug
(Behind Guard)
Ammeter