beautypg.com

Snorkel MB20-sn1000+ User Manual

Page 21

background image

2 - 11

2. Operation & Specifications

E

MERGENCY

S

ITUATIONS

In any emergency situation, the immediate action is to push the red “Emergency Stop”

button. This will instantly cut of all electrical power to the controls. The button must be

twisted in a clockwise direction in order to recommence control.

However, the switch should be reset only when it is safe to do so.

If the Continuous Audible warning alarm sounds, normal control functions will cease to operate.

This will be due to the following problem;

• The Tilt Sensor has been activated

E

MERGENCY

L

OWERING

(

BY HAND

)

Should the machine become inoperable when elevated request a person on the

ground to lower the platform using the emergency lowering valves. Lower the mast

structure before lowering the jib/platform structure.

NOTE:

Lower the masts fully before lowering the jib structure.

C A U T I O N

!

!

During manual emergency lowering,

extreme care must be taken

to ensure that the person carrying out the task is not struck by the

jib or platform structure.

Figure 8: Emergency Lowering - Mast Valve

Figure 9: Emergency Lowering - Jib Valve

M

ANUAL

R

OTATION

1. Lower the masts and jib fully before manually slewing the assembly. Press the

Emergency Stop Button to prevent inadvertent powered motion.

2. Locate the opening behind the front right drive wheel. Apply a 23 mm socket wrench

with extension bar to the shaft and turn to rotate the elevating assembly. (Turning the

front wheel fully to one side will facilitate this operation).

Locate the red lever behind the

mast cover inspection door on the

left hand side of the machine. By

pushing the lever up, the mast will

descend fully under gravity.

Releasing the spring-loaded lever

will cease this operation

immediately if required.

The Jib may be manually lowered

by operating the manual release

valve located between the Jib

Structure.