29877 080301

MAIN SCREEN

This screen will be shown when the brewer is

ready for use. The screen displays the water tempera-
ture in the tank. When the water in the tank reaches the
correct set temperature, the display will change from
HEATING to READY TO BREW.

PROGRAMMING LOCKOUT SWITCH (mounted on
main control board)

This switch can be set to prevent access to the

programming levels of the brewer. Once all the correct
brew settings are programmed, the operator can set
the switch to the "DISABLE" position to prohibit any-
one from changing the settings.

BREW LOCKOUT

This function allows the operator to prevent or

allow brewing if the water temperature is less than the
set READY temperature.

To access this function screen press and hold the

® symbol. Release the ® when the display reads:

Press here

for NO

Press here

for DONE

Press here

for YES

PROGRAM FUNCTIONS - LEVEL 1

The YES or NO should be flashing. Select YES to

prevent brewing if the water temperature is below the
set READY temperature. Select NO to permit brewing
at any water temperature.

When finished, press and release DONE. This will

exit this function screen and return to the MAIN
SCREEN
on the display.

PROGRAMMING THE BREWER

The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions

are accessed in Level 2.

The following function screens are in order of appearance. Each screen will have instructions on how to access,

and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY -

To exit the programming mode at any time, press and release either of the

pads located on the front switch

panel. The display will return to the MAIN SCREEN.

If none of the five programming switches are pressed within one minute during the setup of the brewer, the

programming of the function screen that is being set will be exited and the display will return to the MAIN SCREEN.

Always remember to place a container and funnel under the sprayhead when operating the brewer during the

set-up of PULSE BREW - SET BY EXAMPLE, CALIBRATE FLOW and testing the brew and bypass valves in SERVICE
TOOLS/TEST OUTPUTS.

PROGRAMMING