4 operating and storage temperature ranges, 5 oscillation / vibration, 3 hydraulic fl uid recommendation – Lukas P 600 OE User Manual
Page 35

35
12.4 Operating and storage temperature ranges
Operating temperature
[°C] /
[°F]
-20 …
+55
-4 …
+131
Ambient temperature
(device in operation)
[°C] /
[°F]
-25 …
+45
-13 …
+113
Storage temperature
(device not in operation)
[°C] /
[°F]
-30 …
+60
-22 …
+140
12.5 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is below
2.5 m/s².
12.2 Noise emissions (based on the EN ISO 3744 standard)
Used power source
Lithium-ion battery
Power supply
Idling (measured at
a distance of 1 m)
[dB(A)]
54
54
Full load
(measured at a
distance of 1 m)
[dB(A)]
71
71
Idling (measured at
a distance of 4 m)
[dB(A)]
53
53
Full load
(measured at a
distance of 4 m)
[dB(A)]
67
67
Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others
Oil temperature range
Oil code
Viscosity rating
Remarks
A
-20 .... +55°C
HM 10
VG 10
Oil temperature range
Oil code
Viscosity rating
Remarks
A
-4.0 .... +131°F
HM 10
VG 10
recommended viscosity range: 10...200 mm²/s
(10…200 cSt.)
Supplied with HM 10 DIN ISO 6743-4.
CAUTION!
Before you use hydraulic fl uids from a different manufacturer, you must contact
LUKAS or an authorised dealer.
12.3 Hydraulic fl uid recommendation