Lukas P 600 OE User Manual
Page 28

28
Fault
Check
Cause
Solution
Pump does not
switch to WORKING
mode after actuating
the connected
rescue unit
Initiation sequence
not allowed to run
completely
Switch unit off, then
switch it on again and
wait for initiation
Control valve of
connected rescue unit
actuated too slowly or
too tentatively.
Actuate the control
valve again.
Rescue unit not
connected correctly
(locking sleeve on
the coupling not fully
rotated to "1")
Turn the locking sleeve
on the coupling fully to
the end position "1".
Pump does not
switch back to ECO
mode
Too low ambient
temperature
No repair or fault
rectifi cation required
The motor / engine
is running, but the
connected rescue
equipment is not
moving / moving
very slowly upon
activation of the
valve.
Check hose
Hose assembly not
connected properly or is
damaged
Check connection of
hose and reconnect if
necessary.
Connect a
different unit and
check whether
it works when
actuated
The previously
connected unit is
defective.
Rectifi cation see
operating instructions of
the connected unit
Mono-coupling (female)
defective
Replace mono-coupling
(female)
P600OE defective
Shut down immediately
and have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS