Lukas P 600 OE User Manual
Page 21

21
Inspections to be carried out:
Visual inspection
• No visible damage to the housing,
• General tightness (leaks),
• ON/OFF switch in proper working order, undamaged
• Couplings must be easy to couple,
• Dust protection caps must be present
• Labels completely existent and legibly,
• Illumination of main switch, work area and tank illumination fully functional.
Battery and power supply
• Casing
undamaged,
• Electrical contact surfaces clean and undamaged
• Cable
undamaged
• Battery(-ies) fully charged (when used)
• Charging state display of lithium/ion battery(-ies) fully functional
Functional check
• no suspicious noises,
• tests at maximum load. When the maximum pressure is achieved, the pump switches
to the ECO mode after a short time. As soon as the pressure drops slightly, the pump
automatically switches back to the working mode.
(Recommendation: use the LUKAS test kit, including testing instructions, for the func-
tion test).
If the noises and suspicions referred to above arise several times in a month, or if maximum
pressure cannot be achieved during the function test, you need to contact LUKAS customer
service immediately. The contact details are given in the Chapter "Fault analysis".