6 operating and storage temperature ranges, 7 oscillation / vibration – Lukas SC 350 E User Manual
Page 42

42
11.6 Operating and storage temperature ranges
Operating temperature
[°C] /
[°F]
-20 … +55
-4 …
+131
Ambient temperature
(device in operation)
[°C] /
[°F]
-25 … +45
-13 …
+113
Storage temperature
(device not in operation)
[°C] /
[°F]
-30 … +60
-22 …
+140
11.7 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
11.5.2 R411E:
Battery type used for device
Lithium / ion
No-load operation
(measuring distance: 1m)
[dB(A)]
78
full load operation
(measuring distance: 1m)
[dB(A)]
79
No-load operation
(measuring distance: 5m)
[dB(A)]
71
full load operation
(measuring distance: 5m)
[dB(A)]
72
11.8 Tightening torques for pivot bolts (cutters and combi tools only)
type
S 311 E
S 700 E
SC 250 E
SC 350 E
pivot bolt
M 24 x 1,5
M32 x 1,5
M 24 x 2
M 24 x 1,5
wrench size
[mm]
36
46
36
36
[in.]
1.42
1.81
1.42
1.42
torque
[Nm]
120 +10
140 + 10
110 +10
120 +10
[lbf.in.] 1,062 + 89
1,239 + 89
890 + 89
1,062 + 89