Troubleshooting – Lukas SC 350 E User Manual
Page 36

36
10. Troubleshooting
Trouble
Control
Cause
Solution
Blades, spreader
arms or cylinder
pistons move slowly
or jerkily when
operated
Battery fully
charged?
Battery fl at
Charge battery
Battery defective
Replace battery
Air in the hydraulic
system
Repair by authorised
dealer, staff specially
trained by LUKAS or
directly by LUKAS
Power supply cable
connected?
Power supply
not properly
connected to the
eDRAULIC device
(not automatically
locked).
Reinsert power
supply into the
connection slot.
Power supply
cable not properly
connected to the
external power
supply.
Reconnect external
power supply.
Power supply or
power supply cable
defective.
Replace power
supply or power
supply cable.
External power
source defective.
Use other external
power source
Blades, spreader
arms or cylinder
pistons do not move
when operated.
Battery fully
charged?
Battery fl at
Charge battery
Battery defective
Replace battery
Power supply cable
connected?
Power supply cable
defective
Replace power
supply cable
Device defective
Repair by authorised
dealer, staff specially
trained by LUKAS or
directly by LUKAS
Device doesn’t
perform at its given
power
Device defective
Repair by authorised
dealer, staff specially
trained by LUKAS or
directly by LUKAS