Error codes – Class1 Vernier Throttle for Cummins User Manual
Page 4
![background image](/manuals/546751/4/background.png)
4
DOC 101058C_c:\manuals\throttles\cummins\cumthrot.p65
Error Codes
Error Codes
The
Class1
Vernier Throttle Interface continuously checks for several errors. Errors are displayed on
the green diagnostic LED. When an error is detected, the error number is flashed on the LED.
Example:
If the data link is not detected, (error 2) the LED will flash twice, pause two seconds and
repeat while the error is present.
Defined Errors
ERROR 1
Thottle Error
This error occurs when the controller does not detect an idle
throttle position. The interface will not take active control unitl the throttle is returned to it’s idle position.
This can also be caused by a miswired throttle connection or shorted wiring.
ERROR 2
No RPM Data
This error indicates that the interface module cannot find engine
RPM data on the J-1922 data link. This usually indicates that the data bus is not connected correctly
or is a bus that does not transmit engine speed.
ERROR 3
Data Link Error
This error indicates that there is a problem with the data bus.
This could be a short to ground or reversed connections.
ERROR 4
Transmit Error
This would indicate that there is a transmit conflict with another
device on the data bus.
ERROR 5
Device Conflict
This error indicates that there is another device on the data bus
transmitting the same commands to the engine.
ERROR 6
J1922 Data
This error indicates that the device does not recognize the data
bus as J1922.
For questions or concerns regarding the Class1 throttle interface:
Call
Class1
at 352-629-5020 or Fax at 352-629-2902
J-1922 Function
Conn.
Pin
Circuit
CELECT
Data +
A
10
22
Data -
A
20
23
CELECT PLUS
Data +
A
5
20
Data -
A
23
21
CELECT PLUS
Data +
OEM IN
P
20
Data -
OEM IN
N
21