Inline Wideband UEGO/AEM F/IC Configuration

With an FIC calibration open, go to Setup>Aux Gauge, and complete the Aux gauge
setup window as shown below in Figure 5.

Figure 5. F/IC Aux Gauge Setup

Connect the WHITE Analog Output + wire to the Aux Gauge input and the BROWN
Analog Output – wire to the sensor ground. Table 5 below lists the Lambda and Sensor
ground pin locations for the different FIC part numbers.

AEM F/IC P/N

Lambda Pin

Sensor GND Pin

30-1910(X)

Pin 18 of 22-pin connector

Pin 5 of 22-pin connector

30-1930(X)

Pin 18 of 22-pin connector
Pin 20 of 20-pin connector

Pin 5 of 22-pin connector

Table 5. F/IC Pin Locations

Displaying Data with a PC/Laptop

Real time AFR data can also be viewed via a pc/laptop using an RS232 serial port
connection. Download the data viewer program and instructions from the AEM
Performance Electronics forum at

www.aemelectronics.com

. . See figure 6.