Calibration – AEM 30-2011 Water Temp Sensor Kit User Manual
Page 2
Calibration
Calibration
Temp ©
Temp (F)
Resistance (Ohms)
100 212
180
70 158
500
40 104
1K5
20 68
3K7
0 32
9K8
-20 -4
29K
-40 -40
100K
12 MONTH LIMITED WARRANTY
Advanced Engine Management Inc. warrants to the consumer that all AEM High Performance products will be free from defects in material and
workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12-month warranty period will be
repaired or replaced at AEM’s option, when determined by AEM that the product failed due to defects in material or workmanship. This warranty is
limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be
responsible for special, incidental or consequential damages or cost incurred due to the failure of this product. Warranty claims to AEM must be
transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-
transferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Improper use or installation, accident, abuse,
unauthorized repairs or alterations voids this warranty. AEM disclaims any liability for consequential damages due to breach of any written or implied
warranty on all products manufactured by AEM. Warranty returns will only be accepted by AEM when accompanied by a valid Return Goods
Authorization (RGA) number. Product must be received by AEM within 30 days of the date the RGA is issued.
Please note that before AEM can issue an RGA for any product, it is first necessary for the installer or end user to contact the AEM Performance
Electronics tech line at 1-800-423-0046 to discuss the problem. Most issues can be resolved over the phone. Under no circumstances should a system
be returned or a RGA requested before the above process transpires.
Need additional help? Contact the AEM Performance Electronics tech department at
1-800-423-0046 or [email protected], or visit the AEM Performance Electronics forum at
http://forum.aempower.com/forum/
Table 1. Sensor Calibration